6-105
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
1-2. S VIDEO OUT Y Level Adjustment (VC-543 board)
Mode
VCR mode
Signal
No signal
Measurement Point
Y signal terminal of S VIDEO plug
of A/V Remote connector (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25 (NTSC)
7E (PAL)
Specified value
A = 1000
±
14 mVp-p
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
25
Change the data and set the Y
signal level (A) to the
specified value.
3
C
25
Press PAUSE (Write) button.
4
C
7E
Set a value obtained by
subtracting 3 from the
fore mentioned data, and
press PAUSE (Write) button.
5
Perform “Processing after
Complete Adjustment”.
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
7E
Change the data and set the Y
signal level (A) to the
specified value.
3
C
7E
Press PAUSE (Write) button.
4
C
25
Set a value obtained by
adding 3 to the
fore mentioned data, and
press PAUSE (Write) button.
5
Perform “Processing after
Complete Adjustment”.
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the speci-
fied values of “Origin Oscillation Check” of “1-3. CAMERA SYS-
TEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. S VIDEO OUT Y level adjustment
2. S VIDEO OUT chroma level adjustment
3. VIDEO OUT level check
4. COMPONENT OUT Y level adjustment
5. COMPONENT OUT Pr level adjustment
6. COMPONENT OUT Pb level adjustment
1.
S VIDEO, VIDEO OUT Adjustment
1-1. Preparations
Perform the following data setting before the “S VIDEO,
VIDEO OUT Adjustment”.
Order Page Address Data
Procedure
1
Set the unit to VCR mode.
2
0
01
01
3
7
83
03
4
3
71
01
Press PAUSE (Write) button.
5
0
10
01
6
C
0F
10
Press PAUSE (Write) button.
(1C)
7
8
00
01
Press PAUSE (Write) button.
(18)
8
8
01
60
Press PAUSE (Write) button.
(18)
9
8
06
55
Press PAUSE (Write) button.
(18)
10
8
04
C0
Press PAUSE (Write) button.
(18)
11
Wait for 3.5 seconds.
12
0
10
00
13
0
FF
3E
14
B
00
02
15
C
85
Check the data is “55”.
16
0
FF
00
Fig. 6-3-3
H
A
Summary of Contents for DSR-PD198P