6-26
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
5.
Zoom Ring Adjustment (MR Sensor)
The manual zoom ring MR adjustment is carried out automati-
cally.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6D
6E
Adjustment Address
A9 to AC, AF
FC to FF
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6D, 6E, set data: 06 to
page: 0, address: 10, and then select pages D, E. By this
data setting, the pages 6D, 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 3)
Turn the zoom ring manually
in one direction slowly.
3
It should be turning several
times.
Continue to turn till the end of
adjustment.
4
6
01
5B
Press PAUSE (Write) button.
(Note 4)
5
6
02
Check the data changes to “01”.
6
Wait for 10 seconds.
7
6
0C
Check the data is “00”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 4:
The adjustment data will be automatically input to page:
6D, address: A9 to AC, AF and page: 6E, address: FC to
FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
RadarW
RadarW
RadarW
6.
Focus Ring Adjustment (MR Sensor)
The manual focus ring MR adjustment is carried out automati-
cally.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6D
6E
Adjustment Address
A5 to A8, AD to AF
FA, FB
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6D, 6E, set data: 06 to
page: 0, address: 10, and then select pages D, F. By this
data setting, the pages 6D, 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 3)
Turn the focus ring manually
in one direction slowly.
3
It should be turning several
times.
Continue to turn till the end of
adjustment.
4
6
01
59
Press PAUSE (Write) button.
(Note 4)
5
6
02
Check the data changes to “01”.
6
Wait for 10 seconds.
7
6
0C
Check the data is “00”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 4:
The adjustment data will be automatically input to page:
6D, address: A5 to A8, AD to AF and page: 6E, address:
FA, FB.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
RadarW
RadarW
RadarW
RadarW
RadarW
Summary of Contents for DSR-PD198P
Page 445: ......