6-40
HVR-Z5C/Z5E/Z5J/Z5N/Z5P/Z5U
25. Auto White Balance Check (ND2)
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Clear chart (Color reproduction
adjustment frame)
Filter
ND filter 1.0, 0.4 and 0.1
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified Value
Data of page: 6, address: 0C is “00”
Note 1:
Perform “Auto White Balance Standard Data Input
(ND2)”, “LV Standard Data Input” and “Auto White Bal-
ance Adjustment (ND2)” before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
Procedure
1
0
01
01
2
6
9B
Check the bit value of bit2 is
“0”. (Note 3)
3
6
99
Check the data is “02”.
4
6
07
Check the data is “04”.
5
6
40
01
6
6
41
01
7
6
CA
85
8
6
C9
10
OUTDOOR white balance check
9
6
01
4F
Press PAUSE (Write) button.
10
6
02
Check the data changes to
“01”.
11
6
0C
Check the data is “00”.
12
6
01
00
Press PAUSE (Write) button.
INDOOR white balance check
13
6
01
0F
Press PAUSE (Write) button.
14
6
02
Check the data changes to
“01”.
15
6
0C
Check the data is “00”.
16
6
01
00
Press PAUSE (Write) button.
Order Page Address Data
Procedure
InOut check
17
Place the ND filter 1.5 (1.0
+0.4 + 0.1) on the lens.
18
6
C9
11
19
6
13
BF
20
Wait for 1 second.
21
6
01
4B
Press PAUSE (Write) button.
22
6
02
Check the data changes to
“01”.
23
6
0C
Check the data is “00”.
24
6
01
00
Press PAUSE (Write) button.
25
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Note 3:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
C9
00
2
6
CA
00
3
6
40
00
4
6
41
00
5
6
13
00
6
0
01
00
Summary of Contents for DSR-PD198P