3-5
DSR-570WS/570WSP V1
Error Codes (
Er02-Er33
Er02-Er33
Er02-Er33
Er02-Er33
Er02-Er33
)
Error code
Er02-098
Er02-503
Er02-554
Er02-574
Er02-594
Er02-603
Er02-654
Er02-674
Er02-694
Er02-874
Er07-042
Er08-032
Details
Detected abnormal current
of reel motor.
Detected tape slack during
SEARCH, F.FWD/REW.
Could not detect the S reel
FG output during
SEARCH, F.FWD/REW.
Could not detect the T reel
FG output during
SEARCH, F.FWD/REW.
Could not detect the S/T
reel FG output during
SEARCH, F.FWD/REW.
Detected tape slack during
PLAY/REC.
Could not detect S reel FG
output during PLAY/REC.
Could not detect T reel FG
output during PLAY/REC.
Could not detect S/T reel
FG output during PLAY/
REC.
Could not detect the T reel
FG output during
unthreading.
Detected capstan speed
problem.
Cannot recover from drum
speed problem.
Test mode for
checking/Possible failures
Test mode
Capstan test mode 610
Reel test mode 611
Possible causes
.
The tape is cut or jammed.
.
The reel torque cannot be
adjusted
.
Faulty operations of the
capstan motor or drive
circuit (SV-213 board/
IC300)
.
Faulty operations of the
pinch roller block.
.
Faulty operations of the
brake
.
Reel FG system circuit (SV-
213 board/IC2, IC3, IC6)
problems
.
Faulty operations of reel
brake
.
Disconnection or faulty
connection of flexible board
(SE-297 board)
.
Problems or faulty
disconnection of reel motor
.
Faulty operations of reel
table, etc.
Test mode
Capstan test mode 610
Possible causes
.
Capstan free speed
adjustment (capstan FG
duty ratio adjustment)
problems
.
Faulty operations of capstan
motor or drive circuit (SV-
213 board/IC300)
.
Capstan FG system circuit
(SV-213 board/IC301,
IC302) problems
.
Disconnection or faulty
connection of flexible board
connecting capstan motor
Test mode
Drum test mode 612
Possible causes
.
Drum free speed
adjustment (drum FG duty
ratio adjustment) problems
.
Faulty operations of drum
motor or drive circuit (SV-
213 board/IC400)
.
Drum FG system circuit
(SV-213 board/IC401,
IC402) problems
.
Disconnection or faulty
connection of flexible board
connected to the drum
Operations when
errors occur
When errors occur, SHUT
OFF operations are
performed, and only the
EJECT mode is accepted.
When errors occur, SHUT
OFF operations are
performed. EJECT mode
cannot be accepted.
When errors occur, SHUT
OFF operations are
performed, and only the
EJECT mode is accepted.
When errors occur, SHUT
OFF operations are
performed, and only the
EJECT mode is accepted.
Error detection method
The mechanism control
MICRO COM. could not
detect S reel FG (SE-297
board/PH1) T reel FG (SE-
297 board/PH2) output, or
detected abnormal current
of the reel motor.
*
MICRO COM. means the
microcomputer.
The mechanism control
MICRO COM. could not
detect CAPSTAN FG
output or detected speed
problem.
The mechanism control
MICRO COM. could not
detect drum motor FG
output or detected speed
problem.
Summary of Contents for DSR-570WS
Page 1: ...DIGITAL CAMCORDER DSR 570WS DSR 570WSP SERVICE MANUAL Volume 1 1st Edition ...
Page 14: ......
Page 18: ......
Page 60: ...2 42 DSR 570WS 570WSP V1 1 2 3 4 5 6 7 8 90 ...
Page 68: ......
Page 86: ......
Page 118: ......
Page 198: ......
Page 204: ......
Page 222: ......
Page 248: ......
Page 249: ......