
7-11
DSR-570WS/570WSP V1
6. Adjust the RF waveform on the exit side to
become flat by turning the flange of the TG-5
guide.
7. Be sure to finish the adjustment by turning the
flange of the TG-5 guide clockwise.
m
.
If turning the flange of the TG-5 guide clockwise
too much, return the flange back to the original
position and re-start the adjustment. Finish it by
turning the flange clockwise.
.
Do not turn the tilt adjustment screws of the TG-4
and TG-5 guides.
8. Set the REV search mode, and check that there
are no curls formed at the lower flange of the
TG-2 guide. If curled, perform steps (1), (2)
and (3).
(1)
Rotate the upper flange of the TG-2 guide
in the clockwise direction to remove the
curls.
(2)
Rotate the upper flange of the TG-3 guide
in the counterclockwise direction by 180
d
,
and check that the tape rises. Then return
the nut to its original position.
(3)
If not certified the specification, Perform
the step 4 and step 5.
Summary of Contents for DSR-570WS
Page 1: ...DIGITAL CAMCORDER DSR 570WS DSR 570WSP SERVICE MANUAL Volume 1 1st Edition ...
Page 14: ......
Page 18: ......
Page 60: ...2 42 DSR 570WS 570WSP V1 1 2 3 4 5 6 7 8 90 ...
Page 68: ......
Page 86: ......
Page 118: ......
Page 198: ......
Page 204: ......
Page 222: ......
Page 248: ......
Page 249: ......