10-12
DSR-570WS/570WSP V1
4
3
2
1
E
D
C
B
A
FP-118A BOARD (B SIDE)
TP201
TP603
TP1 TP2
TP402
TP401
TP602 TP601
TP200
CV200
RV403
RV601
RV602
10-4-1. Audio Level Volume Reference
Position Adjustment
Equipment:
Audio level meter
Audio signal generator
Preparations:
.
AUDIO INPUT CH-1/CH-2: 1 kHz,
+
4.0 dBu
.
EE mode
Test point:
CH-1: TP401/FP-118A board (E-3)
CH-2: TP402/FP-118A board (E-3)
Adjusting point
: CH-1 AUDIO LEVEL adjustment
control
1
RV401/FP-118A board
CH-2 AUDIO LEVEL adjustment
control
1
RV402/FP-118A board
Specification:
_
10.3
±
0.2 dBu
10-4-2. Monitor Output (LINE OUT) Level
Adjustment
Equipment:
Audio level meter
Audio signal generator
Preparations:
.
AUDIO INPUT CH-1/CH-2: 1 kHz,
+
4.0 dBu
.
Terminate the following monitor
outputs with 47 k
Z
resistors.
CH-1: TP601/FP-118A board
CH-2: TP602/FP-118A board
.
EE mode
Test point:
CH-1: TP601/FP-118A board (D-3)
CH-2: TP602/FP-118A board (D-3)
Adjusting point:
CH-1:
1
RV601/FP-118A board (D-4)
CH-2:
1
RV602/FP-118A board (D-4)
Specification:
_
10.0
±
0.5 dBu
10-4-3. Limiter Level Adjustment
Equipment:
Audio level meter
Audio signal generator
Preparations:
.
AUDIO SELECT SW CH-1: AUTO
.
AUDIO SELECT SW CH-2: AUTO
.
[REAR PANEL] CH-1: LINE or
MIC
.
[REAR PANEL] CH-2: LINE or
MIC
.
EE mode
Adjusting procedure
1. Input the
+
20 dB signal (for reference signal) to
AUDIO INPUT CH-1/CH-2.
LINE: 1 kHz,
+
24 dBu
(Reference signal; 1 kHz,
+
4 dBu)
MIC: 1 kHz,
_
40 dBu
(Reference signal; 1 kHz,
_
60 dBu)
2. Adjust the level within the specification.
Test point:
TP401/FP-118A board (E-3)
Adjusting point:
1
RV403/FP-118A board (E-3)
Specification:
_
8.3
±
0.2 dBu
Summary of Contents for DSR-570WS
Page 1: ...DIGITAL CAMCORDER DSR 570WS DSR 570WSP SERVICE MANUAL Volume 1 1st Edition ...
Page 14: ......
Page 18: ......
Page 60: ...2 42 DSR 570WS 570WSP V1 1 2 3 4 5 6 7 8 90 ...
Page 68: ......
Page 86: ......
Page 118: ......
Page 198: ......
Page 204: ......
Page 222: ......
Page 248: ......
Page 249: ......