ELIXO 2000 230V RTS
EN
2
Copyright
©
2018 SOMFY ACTIVITES SA. All rights reserved.
WARNING
Any use of this product outside the scope application de-
scribed in these instructions is prohibited (see "Field of
application" paragraph in the installation manual).
The use of any accessories or components not recom-
mended by Somfy is prohibited, as personal safety can-
not be guaranteed.
Any failure to comply with the instructions given in this man-
ual shall exclude Somfy from all liability and invalidate the
Somfy warranty.
If in any doubt when installing the motorisation or to find out
more, visit the website www.somfy.com.
The instructions may be modified if and when there is a change
to the standards or to the motorisation.
1.3. Preliminary checks
1.3.1. Installation environment
ATTENTION
Do not spray water onto the motorisation.
Do not install the motorisation in an explosive environ-
ment.
Check that the temperature range marked on the motori-
sation is suited to the installation location.
1.3.2. Condition of the gate to be motorised
Before installing the motorisation, check that:
• the gate is in good mechanical condition
• the gate is stable regardless of its position
• the structures supporting the gate allow the motorisation
to be fixed securely. Strengthen these if necessary.
• the gate can be opened and closed properly using a force
of less than 150 N.
1.4. Risk prevention
WARNING
Risk prevention - motorisation of a sliding gate for
residential use
Ensure that any danger zones (crushing, cutting, trapping)
between the motorised section and the surrounding fixed
sections created by the opening of the motorised section
are avoided or indicated on the installation.
Permanently affix the crushing warning labels near to any
fixed control devices, and so that they are extremely vis-
ible to the user.
Zone 1
Zone 2
Zone 3
Zone 4
Zone 4
Zone 5
Risk zones: measures to be taken to eliminate risks.
RISK
SOLUTION
ZONE 1
Risk of crushing when
closing
Protection by safety edge(s).
Obstacle detection must be
confirmed as compliant with
Appendix A of standard EN 12
453.
For operation with automatic
closing, install photoelectric
cells (see installation manual).
ZONE 2
Risk of trapping and
cutting on the surface of
the gate
Protection by safety edge(s).
Obstacle detection must be
confirmed as compliant with
Appendix A of standard EN 12
453.
Eliminate any gap ≥ 20 mm
ZONE 3
Risk of crushing with an
adjoining fixed section
upon opening
Protection by safety edge(s).
Obstacle detection must be
confirmed as compliant with
Appendix A of standard EN 12
453.
Protection by means of safety
distances (see figure 1).
ZONE 4
Risk of trapping and
crushing between the
roller rails and bearings
Eliminate all sharp edges on
the guide rails.
Eliminate any gap ≥ 8 mm
between the rails and the
bearings.
ZONE 5
Risk of movement force
and crushing at the pin-
ion/rack connection
Eliminate any gap ≥ 8 mm be-
tween the pinion and the rack.
No protection is required if the gate has continuous control
or if the danger zone is more than 2.5 m above ground or any
other permanent access level.
Figure 1 - Safety distances
1.5. Electrical installation
DANGER
The installation of the power supply must comply with
the standards in force in the country in which the motor-
isation is installed, and must be carried out by qualified
personnel.