EN
ELIXO 2000 230V RTS
9
Copyright
©
2018 SOMFY ACTIVITES SA. All rights reserved.
7.3. Memorising the 2- or 4-button remote controls
for pedestrian opening - Fig. 22
1)
Press the
PROG
button on the control unit for 2 seconds.
The indicator light is lit constantly.
2)
Press the
PROG
button a second time.
The indicator light flashes once slowly.
3)
Press the button of the remote control that will open the gate for pe-
destrians.
The indicator light flashes; the remote control has been stored.
8.
CLEARING THE REMOTE CONTROLS
AND ALL SETTINGS
8.1. Clearing the settings - Fig. 23
Attention
If the settings are deleted, they are reset to the factory values. It
is important to set the gate opening direction again and to conduct
auto-programming again.
1)
Select
DEFAULT
in the control unit menu.
2)
Press
OK
on the control unit to confirm the factory configuration reset
of the control unit.
8.2. Clearing the memorised remote controls - Fig 24
Press the
PROG
button on the control unit for 7 seconds.
The indicator light flashes slowly; all remote controls have been cleared.
9. DIAGNOSTIC AND TROUBLESHOOTING
9.1. Diagnostics
Code
Description
Comments
StrE
Activation of the external
radio start input
oPEn
Activation of the OPEN
input
cLS
Activation of the CLOSE
input
PEd
Activation of PED input
StoP
Activation of the STOP
input
PhoP
Activation of photoelectric
cells input active when
opening
PhCL
Activation of photoelectric
cells input active when
closing
bAr
Activation of safety edge
input
SWC
Activation of the motor
closing end limit input
SWo
Activation of the motor
opening end limit input
SEt
Auto-programming in
progress
Er02
Safety edge autotest
failure
Check connection and/or settings.
Er03
Autotest failure of photo-
electric cells active when
opening
Check connection and/or settings.
Code
Description
Comments
Er04
Autotest failure of photo-
electric cells active when
closing
Check connection and/or settings.
Er1X
*
Circuit board equipment
test error
Check connections on the motor.
Equipment problems on the
circuit board; contact Somfy.
Er3x
*
Obstacle detection
Check the presence of an
obstacle.
Er7x
*
System supervision inter-
nal control error
Try to switch the circuit board
off and on again. If the problem
persists, contact Somfy.
*
x
= 0, 1, ....., 9, A, B, C, D, E, F
10. TECHNICAL
DATA
Power supply
220-230 Vac 50/60 Hz
Power consumption
750 W
Maximum torque
40 Nm
Speed 9 m/min
Maximum gate leaf
weight
2000 kg
Maximum gate leaf length 20 m
Lubrication
ERGOIL oil bath
Manual manoeuvring
Release using individual key
Climatic operating con-
ditions
- 20°C/+ 55°C - IP 44
Noise level
< 70 dBA
Radio frequency
433.42 MHz
< 10 mW
Number of storable
channels
128