7. ADVANCED PARAMETER SETTING
7.1. Navigating in parameter setting mode
Buttons
Function
OK
• Press twice to access the settings menu
• Press once to confirm:
-
the parameter selection
-
the parameter value
+ OR -
Navigating the parameter list
Modifying the value of a setting
+ AND -
Exiting the settings menu
7.2. List of settings (menus and sub-menus)
In the table, the
value in bold type
corresponds to the
default value
.
Menu
Sub-menu
Val.
Description
PArAM
oPEn
worK.t
5 to 300 (
5
)
Maximum operating time when opening (in seconds)
Adjusted automatically during auto-programming
cLS worK.t
5 to 300 (
5
)
Maximum operating time when closing (in seconds)
Adjusted automatically during auto-programming
tcA
0 to 180
(
40
)
Automatic closing timeout
oP.dISt.
SLoUd
0 to 99 (
2
)
Deceleration distance when opening expressed as a percentage of the total travel (%)
If it is less than 50 cm, it will automatically be adjusted during auto-programming
cL.dISt.
SLoUd
0 to 99 (
2
)
Deceleration distance when closing expressed as a percentage of the total travel (%)
If it is less than 50 cm, it will automatically be adjusted during auto-programming
PArtIAL
oPEnInG
10 to 50
(
20
)
Pedestrian opening distance expressed as a percentage of the total travel (%)
oP.ForcE
1 to 99 (
99
) Force exerted by the gate when opening (%)
Adjusted automatically during auto-programming
Warning
If one of the settings is modified,
the installer must check that
obstacle detection complies with
Appendix A of standard EN 12
453. If necessary, install a safety
edge and check that compliance
is obtained.
Failure to follow this instruction
may result in serious injury, e.g.
due to crushing by the gate.
cLS.ForcE
1 to 99 (
99
) Force exerted by the gate when closing (%)
Adjusted automatically during auto-programming
oP.SLwd.
ForcE
1 to 99 (
99
) Force exerted by the gate when slowing down during opening (%)
Adjusted automatically during auto-programming
cLS.SLwd.
ForcE
1 to 99 (
99
) Force exerted by the gate when slowing down during closing (%)
Adjusted automatically during auto-programming
brAKE
0 to 99 (
0
)
Braking during slowing phase (%)
LoGIc
tcA
0
Automatic closing not activated
1
Automatic closing activated
FASt cLS.
0
Quick closing not activated
1
Quick closing activated: closing 3 s aer the cells are cleared without waiting for the end of the automatic
closing timeout configured
StEP-
by-StEP
MovEMnt
0
Sequential
Each press on the remote control causes the motor to move (initial
position: gate closed) as per the following cycle: open, stop, close,
stop, open, etc.
With following
LoGIc
parameter
setting:
tcA
= 0
IbL oPEn
= 0
IbL tcA
= 0
Sequ automatic timed close
Operation in automatic closing mode is only authorised if photoelec-
tric cells with autotest function are installed (see Fig. 19)
In sequential mode with automatic timed close:
• the gate closes automatically aer the timeout programmed in the
PArAM
/
tcA
menu
• pressing the button on the remote control interrupts the
opening movement then the gate closes automatically aer the
programmed timeout
• pressing the button on the remote control interrupts the closing
movement and the gate will not close automatically.
With following
LoGIc
parameter
setting:
tcA
= 1
IbL oPEn
= 0
IbL tcA
= 0