7.8 Setting the timed close - Fig. 21
Set the timed close (up to 120 s delay) with the
tIME
potentiometer if the
"Sequ automatic timed close", "Automatic" or "Aut cell blocking"
operating mode is selected:
-Turn the potentiometer to the right to increase the time delay.
-Turn the potentiometer to the left to decrease the time delay.
8 - PRogRaMMIng
thE REMotE ContRolS
8.1 Memorising the 2- or 4-button remote control for
pedestrian opening - Fig. 22
[1].
Press and hold (2 s) the
PRog
button (7, Fig. 3).
The red indicator will come on permanently.
[2].
Press the
PRog
button a second time.
The red indicator light flashes slowly.
[3].
Press the button of the remote control that will open the gate for
pedestrians.
The red indicator light flashes, the remote control has been memorised.
8.2 Memorising 3-button remote controls - Fig. 23
[1].
Press and hold (2 s) the
PRog
button (7, Fig. 3).
The red indicator will come on permanently.
[2].
Press a button on the remote control.
The red indicator light flashes slowly, the remote control has been
memorised.
Button functions on a 3-button remote control
my
Complete opening
Stop
Complete closing
9 - ClEaRIng thE REMotE ContRolS
anD all SEttIngS
9.1 Clearing the memorised remote controls - Fig 24
Causes all memorised remote controls to be cleared.
9.2 Clearing the programming - Fig. 25
Clears the programming: offset between the gate leaves, slowdown zone at
end of travel.
10 - DIagnoStICS
10.1 troubleshooting the safety edge
Position the jumper JP11 as shown in the figure below:
TIME
SET
P
O
W
E
R
1
2
3
4
5
6
7
8
9 10 11 12
JP11
JP11
The safety edge is deactivated.
DangER
The motorisation is operating with no safety device.
Once troubleshooting is complete, return the jumper to its original position and
test the safety edge.
11 - tEChnICal Data
gEnERal SPECIFICatIonS
Power supply
220/230 V - 50/60 Hz
Max. power consumption
max motors 520 W
Climatic operating conditions
- 20° C / + 60° C - IP44
Somfy radio frequency
RTS 433.42 MHz
Number of memorisable channels
128
ConnECtIonS
Safety input
configurable
during closing
Type
Dry contact: NC
Compatibility
TX/RX photoelectric cells - Reflex
photocell - 8.2 kΩ resistive safety edge
Wired control input
Dry contact: NO
Orange light output
230 V - 60 W
Safety input test output
Yes: autotest for cell active during
closing
Accessories power supply output
24 Vac - 315 mA max
Offset aerial input
Yes: RTS antenna compatible
(part no.: 2400472)
oPERatIon
Automatic closing mode
Yes: programmable timed reclosing
from 0 to 120 s
Orange light warning
Programmable: without or with
warning (fixed at 2 s)
Pedestrian opening control
Yes: complete opening of motorised
gate leaf by M1
Coupling speed when closing
By default 33% of normal speed
Lock release - electric lock release
Configurable: active - inactive
Gate leaf offset
Configurable