animeo KNX/EIB 4 AC MoCo • REF. 5050779 -
6/31
Checking the running direction of the blinds
Group control of the motors 1 - 4 over the group control input
Over the group control input the running directions of the connected motors can be tested. All four motor outputs are switched together. This input
can become disabled in the ETS parameters. In the case of a bus voltage failure it is always enabled in order to make an emergency operation
possible.
m
Absolute guarantee with start-up that the motors run into the correct direction. By cable links at the group control input this test can be
accomplished.
2.1
m
As soon as 230 V and the EIB bus voltage supply are attached the „US“ LED will blink regularly.
The device is operational when the „US“ LED is blinking continuously.
Check the correct direction of the end product
DOWN:
The end product heads in the down direction (cable link between C +
▼
)
STOP:
The end product stops (Cable link between C +
▼
+
▲
)
UP:
The end product heads in the up direction (cable link between C +
▲
)
Connections to ...
Cables
Twisted pairs
Max. distance
Motors
Min.: 4 x 0.75 mm
2
/16 AWG
Max.: 4 x 2.5 mm
2
/13 AWG
-
150 m
Switches
Min.: 3 x 0.6 mm
2
/19 AWG
Max.: 3 x 2.5 mm
2
/13 AWG
Recommended
150 m
Group control
Min.: 3 x 0.6 mm
2
/19 AWG
Max.: 3 x 1.5 mm
2
/13 AWG
Recommended
1000 m
EIB bus
2 x 2 x 0.8 mm
2
Required, following KNX/EIB
topology guidelines
230 V AC
Min.: 3 x 0.75 mm
2
/16 AWG
Max.: 3 x 2.5 mm
2
/13 AWG
CABLE