Communication Ports Status
D e v P r o t # #
R S 4 8 5 - 1 < S E > < S > < - - >
Z i g B e e < S E > < M P S > < - - >
l
##
: The total number of slaves detected on the specific port
l
Dev
: The type of device that was configured to a specific port (based on the port’s functionality), as
follows:
o
SE
: SolarEdge device (default)
o
LGR
: Non-SolarEdge logger
o
MLT
: Multiple devices, such as meters and batteries
l
PROT
: The protocol type to which the port is set:
o
For a SolarEdge device:
RS485 protocol
ZigBee protocol
S
: SolarEdge slave
M
: SolarEdge master
P2P
: ZigBee point-to-point
MPM
: ZigBee multipoint master (for the SolarEdge ZigBee
home gateway or for load management by the inverter)
MPS
: ZigBee multipoint slave (for a ZigBee router card)
o
For electricity meters, refer to the
application note - Connecting an Electricity Meter
to SolarEdge Devices
http://www.solaredge.com/files/pdfs/solaredge-meter-
.
o
SS
: SunSpec - for a non-SolarEdge logger (monitoring and control)
Smart Energy Management Status
This screen is displayed only when Smart Energy Management is enabled. The screen shows energy details
of the site:
S i t e L i m i t :
7 . 0 k W
S i t e P r o d :
1 0 . 0 k W
S i t e E x p o r t :
4 . 0 k W
S e l f - c o n s u m e :
6 . 0 k W
l
Site Limit
: The limit that was defined for the site
l
Site Prod
: The power produced by the site
l
Site Export
: The power that is fed into the grid
l
Self-consume
: The PV power consumed by the site
For more information, refer to the
Export Limitation Application Note
, available on the
SolarEdge website at
https://www.solaredge.com/sites/default/files/export_limitation_