Additional StorEdge Troubleshooting
Some of the troubleshooting procedure may require removing the covers of system components
(inverter, battery, Connection Unit, or meter). Be sure to disconnect all power sources to avoid
electrocution.
For opening the cover refer to on page 44.
WARNING!
ELECTRICAL SHOCK HAZARD. Do not touch uninsulated wires when the inverter cover is removed.
RISQUE D’ÉLECTROCUTION, ne touchez pas les fils non isolés lorsque le couvercle de l'onduleur est
retiré.
Problem
Description or possible cause
Troubleshooting
During normal operation (grid
supplies power), no power to the
backup loads while the inverter is
producing power
The main circuit breakers or loads
circuit breakers in the backed up
loads panel have been triggered
Check that the backed-up loads
breakers on the CB panel are in the UP
position
Internal circuit breaker has been
triggered
Check that the AC circuit breaker in
the Connection Unit is in the UP
position (see
)
The inverter is malfunctioning
Restart the inverter
If the problem persists, move the
AC bypass switch in the Connection
Unit to position 2 (see
) to
supply power to the loads until the
inverter problem is solved (contact
SolarEdge support if required). Then
move to position 1.