The cellular kit can be purchased separately and assembled during system installation.
The kit is provided with a user manual, which should be reviewed prior to connection.
Refer to
https://www.solaredge.com/sites/default/files/cellular_cdma_kit_installation_
.
Communication Connectors
Two communication glands are used for connection of the various communication options. Each gland
has three openings. The table below describes the functionality of each opening. Unused openings should
remain sealed.
Gland#
Opening
Functionality
Cable Size (diameter)
1
(PG16)
One small
External antenna cable
2-4 mm
Two large
Ethernet connection (CAT5/6),
ZigBee, Cellular
4.5-7 mm
2
(PG13.5)
All three
RS485, power reduction
2.5-5 mm
Figure 32: Communication Glands
The communication board has a standard RJ45 terminal block for Ethernet connection, and a 9-pin
terminal block for RS485 connection, as shown below:
Figure 33: Internal connectors