![SolarEdge SE3K-N4 Installation Manual Download Page 20](http://html1.mh-extra.com/html/solaredge/se3k-n4/se3k-n4_installation-manual_1313739020.webp)
l
Mounting hole:
for securing the unit to the bracket and for connecting an optional secondary
grounding cable.
l
Grounding screw
: for connecting an optional secondary grounding cable.
l
AC and DC conduit entries
: Connection points of the Connection Unit.
l
Two communication glands
, for connection of communication options. Each gland has three
on page 54 for more information.
l
ON/OFF/P Switch
:
Figure 7: ON/OFF/P switch
o
ON (1)
- Turning this switch ON (after optimizer pairing) starts the operation of the power
optimizers, enables power production and allows the inverter to begin exporting power to the
utility grid
o
OFF (0)
- Turning this switch OFF reduces the power optimizer voltage to a low safety voltage and
inhibits exportation of power. When this switch is OFF, the Primary and Secondary Units' control
circuitry remains powered up.
o
P
- Moving and releasing the switch allows viewing system information via the LEDs and on the
SolarEdge SetApp mobile application screen and performing functions:
P Position duration
Function
Comments
Switch moved to P for
less than
5 seconds
, then released.
o
Displays production information for 5
seconds on the SetApp screen.
o
Displays error type indications (if exist)
for 5 seconds.
o
Activates the Wi-Fi access point for
connecting to the SolarEdge Inverter
SetApp
While the switch is in
P, all LEDs are ON
Switch moved to P for
more than
5 seconds
, then released.
Starts pairing
LEDs
l
LEDs
: three LEDs indicate, by color and state (on/ off/ blinking
1
/ flickering
2
/alternating
3
), different
system information, such as errors or performance indications.
Generally, the main LED indications are:
l
Blue ON - the inverter is communicating with the monitoring platform
l
Green ON - the system is producing
l
Green blinking - AC is connected but the system is not producing
l
Red ON - system error
1
Blinking = Turns ON and OFF for the same duration
2
Flickering = Turns ON for 100 mS and turns OFF for 5 seconds
3
Alternating = Alternate LEDs flash
Chapter 3: Installing the Primary and Secondary Unit(s)
Three Phase Inverter with synergy technology Guide MAN-01-00402-1.1
19