SECTION 2 - HEATING DATA
Page S2-4
EMPIRICAL TRACKING
The data supplied below is an example of the PCS1Õs actual performance near
Jacksonville, Florida during 1989. It can be observed that the PCS1 raised the poolÕs
temperature from 3 to 8
°
F in a single day. A more typical rise in the poolÕs
temperature is 1 to 2
°
F per day. Thus, over the course of two weeks, the pool is
raised to the desired swimming temperature. The pool in the example below used a
pool blanket during periods of extended non use.
The format provided below is a good one to use for determining the overall
performance of the PCS1 in your own installation. Take the temperature readings at
the same time each morning [7-9 a.m.] and each afternoon [4-6 p.m.].
EMPIRICAL DATA
Date
Air Temp
Conditions
Pool
°
F a.m.
Pool
°
F p.m.
°
F Gained
4/19
87
Sunny
82
87
5
4/20
80
Overcast
85
88
3
4/21
74
Cloudy
---
86
---
4/22
83
Sunny
83
88
5
4/23
85
Sunny
86
91
5
4/24
88
Sunny
87
92
5
4/25
90
Sunny
89
94
5
4/26
90
Sunny
90
98
8
4/27
90
Sunny
96
stopped heat
5/2
84
Sunny
84
90
6
5/2
80
Sunny
86
91
5
What is the PCS1 capable of doing? The following curves show designed
verified performance. The performance curves assume constant temperature
differentials. In reality, the temperature differentials will vary somewhat
throughout the course of the solar heating day.
Summary of Contents for PCS1
Page 7: ...SECTION 1 SYSTEM ARRIVAL Page S1 1 SECTION ONE SYSTEM ARRIVAL...
Page 22: ...SECTION 2 HEATING DATA Page S2 1 SECTION TWO HEATING DATA...
Page 28: ...BTUS Vs GPM BTUS Vs T SECTION 2 HEATING DATA Page S2 7...
Page 34: ...SECTION 3 INSTALLATION Page S3 1 SECTION THREE INSTALLATION...
Page 65: ...Attic Installation Photos SECTION 3 INSTALLATION Page S3 31...
Page 66: ...Attic Installation Photos SECTION 3 INSTALLATION Page S3 32...
Page 88: ...SECTION 4 SERVICE Page S4 1 SECTION FOUR SERVICE...
Page 99: ...Common Questions Page 1 of 10 COMMON QUESTIONS...
Page 109: ...Dictionary of Terms Page 1 of 4 DICTIONARY OF TERMS...