WATTrouter M - user manual
How to fit and setup the device
Page 74 from 79
correspond with reality
does not have accurate data from
utility/billing meters. Furthermore, the
device may be configured improperly, i.e.
does not evaluate the same as your utility
meter does.
Statistics suddenly erased
This is normal
There was a date change in the controller or
power failure during writing the history into
EEPROM.
Cannot pair units via Ethernet
using the S-Connect protocol
The units do not have S-
Connect activated
Activate S-Connect on all units, one unit
must be access point (AP) and the other
units must be stations (STA).
The units are not
connected to the same
local network
Connect all units to the same local network.
Note: Pairing requests do not pass from one
subnet to another, you must use the same
subnet.
The units have either
incorrect network
configuration or are
disconnected
Make sure all units are accessible on local
network (use PING command).