61
14. SETTING-OUT MEASUREMENT
6. Press
[EDIT]
and set the following
items.
(1) Sdist/Hdist/Vdist: distance
from the instrument station to
the position to be set out.
(2) H ang: included angle
between the direction of the
reference and the point to be
set out.
• Pressing
[COORD]
in the
second page allows you to enter
the coordinates of the point to be
set out.
7. Press
[OK]
to set the input values.
8. Rotate the top of the instrument
until “dHA” is 0° and place the
target on the sight line.
9. Press
[OBS]
to start distance
measurement. The target and the
distance of the point to be set out
is displayed (S-O H).
10. Move the prism forward and
backward until the setting-out
distance is 0m. If [S-O H] is “+”,
move the prism toward yourself, if
it is “-”, move the prism away from
yourself.
H
H
H
READ S-O
EDIT
OK
l
4 0 0 0 0 0
H
H
H
a
OBS
S-O
l
REC
a
30R.book 61
ページ
2003年12月16日 火曜日 午後5時15分