37
11. DISTANCE MEASUREMENT
Perform the following settings as preparation for distance measurement.
• Distance measurement mode
• Target type
• Prism constant correction value
• Atmospheric correction factor
• EDM ALC
C
“24.1 Changing Instrument Options
z
EDM Settings /
z
Settings in Config
Mode”
C
CAUTION
• When using the Laser-pointer function, be sure to turn OFF the output laser
after distance measurement is completed. Even if distance measurement is
canceled, the Laser-pointer function is still operating and the laser beam
continues to be emitted. (After turning ON the Laser-pointer, the laser beam is
emitted for 5 minutes, and then automatically switches OFF. But in the Status
screen and when target symbol (ex.
) is not displayed in the Meas mode, the
laser beam is not automatically turned off. )
%
• Make sure that the target setting on the instrument matches the type of target
used. SET automatically adjusts the intensity of the laser beam and switches
the distance measurement display range to match the type of target used. If the
target does not correspond to the target settings, accurate measurement results
cannot be obtained.
• Accurate measurement results cannot be obtained if the objective lens is dirty.
Dust it off with the lens brush first, to remove minute particles. Then, after
providing a little condensation by breathing on the lens, wipe it off with the
wiping cloth.
• During reflectorless measurement, if an object with a high reflective factor
(metal or white surface) is positioned between the SET and the target, accurate
measurement results may not be received.
• Scintllation may affect the accuracy of distance of measurement results. Should
this occur, repeat measurement several times and use the averaged value of
the obtained results.
30R_11.FM 37 ページ 2004年8月23日 月曜日 午後5時25分
Summary of Contents for 30R Series
Page 8: ...vi 30R book vi ページ 2003年12月16日 火曜日 午後5時15分 ...
Page 172: ...29 REGULATIONS 164 CE Conformity Declaration 30R_29 FM 164 ページ 2003年12月18日 木曜日 午後5時11分 ...
Page 173: ...165 29 REGULATIONS 30R_29 FM 165 ページ 2003年12月18日 木曜日 午後5時11分 ...
Page 177: ...30R book 1 ページ 2003年12月16日 火曜日 午後5時15分 ...
Page 178: ...8th ed 13 0408 Printed in Japan 2002 SOKKIA CO LTD 30R_C3C4 FM 2 ページ 2004年8月23日 月曜日 午後5時43分 ...