13. RESECTION MEASUREMENT
56
6. Press
[CALC]
or
[YES]
to
automatically start calculations
after observations of all known
points are completed. Instrument
station elevation and standard
deviation, which describes the
measurement accuracy, are
displayed.
7. Press
[RESULT]
to check the
result.
If there are no problems in the
result, press
{ESC}
and go to step
10.
8. If there are problems with the
results of a point, align the cursor
with that point and press
[BAD]
.
“*” is displayed on the left of the
point.
9. Press
[RE CALC]
to perform
calculation again without the point
designated in step 8. The result is
displayed.
If there are no problems with the
result, go to step 10.
If problems with the result occur
again, perform the resection
measurement from step 3.
10. Press
[OK]
to finish resection
measurement. Only Z (elevation)
of the instrument station
coordinate is set. N and E values
are not overwritten.
Z
Z
R E S U LT
R E C
1 0 . 0 0 0
0 . 0 0 2 2 m
O K
1 s t
2 n d
3 r d
B A D
RE_CALC
RE_OBS
A D D
0 . 0 0 0
- 0 . 0 0 3
- 0 . 0 0 3
4 t h 0 . 0 0 2
Z
30R.book 56
ページ
2003年12月16日 火曜日 午後5時15分
Summary of Contents for 30R Series
Page 8: ...vi 30R book vi ページ 2003年12月16日 火曜日 午後5時15分 ...
Page 172: ...29 REGULATIONS 164 CE Conformity Declaration 30R_29 FM 164 ページ 2003年12月18日 木曜日 午後5時11分 ...
Page 173: ...165 29 REGULATIONS 30R_29 FM 165 ページ 2003年12月18日 木曜日 午後5時11分 ...
Page 177: ...30R book 1 ページ 2003年12月16日 火曜日 午後5時15分 ...
Page 178: ...8th ed 13 0408 Printed in Japan 2002 SOKKIA CO LTD 30R_C3C4 FM 2 ページ 2004年8月23日 月曜日 午後5時43分 ...