29
7. SETTING UP THE INSTRUMENT
X
PROCEDURE Levelling on the screen
1. Press
{ON}
to power on
2. Press
[TILT]
in the second page of
Meas Mode to display the circular
level on the screen.
“ ” indicates bubble in circular
level. The range of the inside circle
is ±3' and the range of the outside
circle is ±6'.
Tilt angle values X and Y are also
displayed on the screen.
3. Center “ ” in the circular level
C
"7.2 Levelling" steps 1 to 2
4. Turn the instrument until the
telescope is parallel to a line
between levelling foot screws A
and B, then tighten the horizontal
clamp.
5. Set the tilt angle to 0° using foot
screws A and B for the X direction
and levelling screw C for the Y
direction.
6. Press
{ESC}
to return to Meas
Mode.
30R.book 29
ページ
2003年12月16日 火曜日 午後5時15分