26. CHECKS AND ADJUSTMENTS
142
The additive distance constant K of the SET is adjusted to 0 before delivery.
Although it almost never deviates, use a baseline with a known distance precision
to check that the additive distance constant K is close to 0 several times a year
and whenever the values measured by the instrument begin to deviate by a
consistent amount. Perform these checks as follows.
%
• Errors in setting up the instrument and reflective prism or in sighting the target
will influence the additive distance constant. Be extremely careful to prevent
such errors when performing these procedures.
• Set up so that the instrument height and the target height are identical. If a flat
place is not available, use an automatic level to make sure the heights are
identical.
X
PROCEDURE Check
1. Find an area of flat ground where
two points 100m apart can be
selected.
Set up the Instrument at point A
and the reflective prism at point B.
Establish a point C half way
between points A and B.
2. Precisely measure the horizontal
distance between point A and
point B 10 times and calculate the
average value.
3. Place the SET at point C directly
between points A and B and set
up the reflective prism at point A.
4. Precisely measure the horizontal
distances CA and CB 10 times
each and calculate the average
value for each distance.
26.7
Additive Distance Constant
30R.book 142
ページ
2003年12月16日 火曜日 午後5時15分
Summary of Contents for 30R Series
Page 8: ...vi 30R book vi ページ 2003年12月16日 火曜日 午後5時15分 ...
Page 172: ...29 REGULATIONS 164 CE Conformity Declaration 30R_29 FM 164 ページ 2003年12月18日 木曜日 午後5時11分 ...
Page 173: ...165 29 REGULATIONS 30R_29 FM 165 ページ 2003年12月18日 木曜日 午後5時11分 ...
Page 177: ...30R book 1 ページ 2003年12月16日 火曜日 午後5時15分 ...
Page 178: ...8th ed 13 0408 Printed in Japan 2002 SOKKIA CO LTD 30R_C3C4 FM 2 ページ 2004年8月23日 月曜日 午後5時43分 ...