115
24. CHANGING THE SETTINGS
&
Prism constant correction
Reflective prisms each have their prism constant.
Set the prism constant correction value of the reflective prism you are using.
When selecting "None (Reflectorless)" in "Reflector", prism constant
correction value is set to "0" automatically.
• The following are samples of the prism constant correction values of
reflective prisms from Sokkia.
Settings in Config Mode
Select “Obs. condition” in Config mode
Items set and options (*: Factory setting)
Dist mode: Sdist*, Hdist, Vdist
Tilt crn (Tilt angle compensation): Yes(H,V)*, Yes(V), No
coll. crn (Collimation correction): Yes*, No
C&R crn.: No*, K=0.142, K=0.20
V manual: Yes, No*
V.obs (Vertical angle display method): Zenith*, Horiz, Horiz 90° (Horizontal ±90°)
Ang. reso. (Angle resolution): SET230R/330R/530R:1
″
*, 5
″
, SET630R:1
″
, 5
″
*
Coord.: N-E-Z*, E-N-Z
AP01 (Constant = 40mm)
Correction Value = -40
)
:
:
:
:
30R.book 115