97
3
Counting
Total key function
Selection
of which functions are to be linked to the sum key
Display totals only
After pressing the function key Total, the total is displayed. The user can then
decide whether the total memory is to be deleted or not.
Press the F2 key to clear the total memory.
Then confirm the confirmation prompt with the F1 to F3 keys and press YES to
print the total.
Total Display/Print/Clear
After pressing the Total function key, the totals are displayed for 3 seconds.
The memory contents are printed out and deleted at the same time. Then
a new totalling operation can be started.
Factory setting: Display/Print/Clear
Clip off factor
Input
in d via numeric keypad
The number of digits by which the scale must be unloaded during totalisation so
that you can store weights in the totalising memory again. If the weight is not
unloaded, it will not be stored in the totalising memory; error message "Error 55
Place weight on scale.
You can enter values between 0 and 30 digits. If you enter 0, you can total the
weight once the stability has been reached.
Factory setting: 15 digit increments
Reference weight fixed
values
Edit
fixed values Reference weight
Selection of existing fixed values from the list
Scroll with the arrow keys F3 and F4.
Call the desired fixed value with F6 Edit.
Edit an existing fixed value from the list.
Press F6 to call up editing of the selected fixed value.
Parameter Name is marked, call via F6 Edit,
Input via keyboard. Accept the input with F6.
(Cancel without accepting the input with F5 Cancel)
Further parameters are processed analogously.
Deleting an existing fixed value
Scroll with the arrow keys F3 and F4.
Delete the marked fixed value with F2 Delete.
The resulting gap in the consecutive numbering is closed.
Save new fixed value
Press F1 New.
The memory location number is assigned by the device. The first number in
brackets indicates the number of free memory locations, the second number the
memory locations occupied by fixed values.
Parameter Name is highlighted, call via F6 Edit, input via keyboard. Accept the
entry with F6 Accept.
(Cancel without accepting the input with F5 Cancel.)
Further parameters are processed in the same way.
Exiting the list Fixed values
Press the F5 Back key to exit the list.
Call fixed values
Selection
of whether the fixed value is called up via memory location number or
article number.
Factory setting: Article number
Clear reference weights
Selection
do not execute or execute
Execute deletes all fixed values in the REF-Fix memory.