Editing an existing fixed value from the list
Edit the selected fixed value via F6 Edit.
Parameter Name is highlighted, call via F6 Edit, input via keyboard.
Accept the entry with F6 (abort without accepting the entry with F5 Abort).
Further parameters are edited in the same way. Only the same number of decimal places can be used for the
tolerance fields Minus and Plus.
Deleting an existing fixed value
Scroll with the arrow keys F3 and F4 or call up via the article number or the sequential number.
Delete the called fixed value with F2 Delete. Answer the confirmation prompt with YES.
The resulting gap in the consecutive numbering is closed.
Save new fixed value
Press F1 New.
The memory location number is assigned by the terminal. The first number in brackets indicates the number
of free memory locations, the second number the occupied memory locations.
Parameter Name is highlighted, call via F6 Edit, input via keyboard.
Accept the entry with F6 (abort without accepting the entry with F5 Abort).
Further parameters are edited in the same way. Only the same number of decimal places can be used for the
tolerance fields Minus and Plus.
Exiting the list Fixed values
Press the F5 Back key to exit the list.
b) Calling up the list of fixed values of control weights for checking:
In Level 1 Control Functions, press the F2 Contr. fix key.
The display shows the last fixed value called up.
Selection within the list
•
Scroll with the arrow keys F3 or F4 until the desired memory location is reached,
Accept the desired fixed value with F6 Accept
•
Direct call via article number or memory location number
Use the numeric keypad to enter the item or memory location number.
(Determining whether the article or memory location number is called up in setting mode, entering the
article number as a search criterion is left-justified, entering the memory location number as a search
criterion is right-justified) Accept the desired fixed value with F6 Accept
When the fixed value is called up, setpoints and tolerances for checking are also accepted, if saved with .
Press the CL key to delete the read-only memory from the working memory.
To delete all stored reference weights, use the "Delete reference weights" function in the setting mode.
Note
If the function read-only memory call via barcode is activated and one is called that is not contained in the
fixed memory, the error message "Error 83 - Fixed value not available" appears. You return to the weighing
mode and the selected function is deleted.