background image

IQMIX25/26/40/41

RollCall Control Panel

Issue 1 Rev 4

Page 43

© 2017 SAM

Where N is the input number

LAN_PORT_

N

_SPEED=

Ethernet connection speed. Valid values are:

10 Mbit/s Full Duplex

10 Mbit/s Half Duplex

100 Mbit/s Full Duplex

100 Mbit/s Half Duplex

1 Gbit/s Full Duplex

No Link

LAN_PORT_

N

_IPADDRESS=

Ethernet port IP address.

LAN_PORT_

N

_MACADDRESS= Ethernet port MAC address.

LAN_PORT_

N

_STATE=

Ethernet connection state. Valid values are:

Active

Inactive

LAN_PORT_

N

_TRAFFIC_IN=

Traffic in. Valid values are:

NNN.n Kbps, Mbps, Gbps

LAN_PORT_

N

_TRAFFIC_OUT= Traffic out. Valid values are:

NNN.n Kbps, Mbps, Gbps

Log Field

Description

Summary of Contents for IQMIX25

Page 1: ...www s a m com User Manual IQMIX25 26 3G HD SD SDI Multi channel 10 25GbE IP Transceiver IQMIX40 41 3G HD SD SDI Multi channel 10 40GbE IP Transceiver...

Page 2: ...horized agents Reproduction or disassembly of embedded computer programs or algorithms prohibited No part of this publication can be transmitted or reproduced in any form or by any means electronic or...

Page 3: ...lifiziertes Personal ACHTUNG Gefahr von Elektroschocks Abdeckungen nicht entfernen Keine vom Benutzer zu wartende Teile Wenden Sie sich ausschlie lich an qualifiziertes Personal L Phase N Nulleiter N...

Page 4: ...ES INGEN BRUGER SERVICERBARE DELE SERVICE M KUN UDF RES AF FAGL RTE PERSONER F 0 J 0 F J Han stik Hun stik F rklaring av S kerhetssymboler Denna symbol h nvisar anv ndaren till viktig information som...

Page 5: ...s a menos que seja efectuadas por t cnicos habilitados Para reduzir o risco de choque el ctrico n o expor este equipamento chuva ou humidade Assegurar que a unidade est sempre devidamente ligada terra...

Page 6: ...Performance of Cables and Connectors SAM products are designed to meet or exceed the requirements of the appropriate European EMC standards In order to achieve this performance in real installations...

Page 7: ...ernet QSFP 21 3 4 DensiShield 21 4 Card Edge LEDs 22 5 RollCall Control Panel 23 5 1 Terminology 23 5 2 Navigating Pages in the RollCall Template 23 5 2 1 Template Pages 23 5 2 2 Setting Values 24 5 3...

Page 8: ...k Address 50 5 17 5 RollTrack Command 50 5 17 6 RollTrack Sending 50 5 17 7 RollTrack Status 50 5 18 Loopback Router 51 5 19 Setup 52 5 19 1 Restart 52 5 19 2 Defaults 53 5 20 Ethernet Front 53 5 20 1...

Page 9: ...ile sending signals uncompressed provides best quality transport although at the expense of bandwidth Encapsulation of signals in a SMPTE 2022 6 transport stream can also be handled to provide compati...

Page 10: ...outputs 2 x 40GbE ports IQMIX4001 3B3 16 channel SDI to IP transceiver with 40GbE interface Up to 16 SDI inputs or outputs 2 x 40GbE ports Includes IQFAN rear panel for additional cooling in IQH3B fr...

Page 11: ...s and 8 SDI outputs 2 x 10GbE ports Includes IQFAN rear panel for additional cooling in IQH3B frame IQMIX2500 2B3 16 channel SDI to IP transceiver with 25GbE interface Up to 16 SDI inputs or outputs 2...

Page 12: ...IQMIX25 26 40 41 Introduction Issue 1 Rev 4 Page 12 2017 SAM Figure 3 IQMIX4010 2B3 Figure 4 IQMIX4011 3B3 Figure 5 IQMIX4100 2B3...

Page 13: ...IQMIX25 26 40 41 Introduction Issue 1 Rev 4 Page 13 2017 SAM Figure 6 IQMIX4101 3B3 Figure 7 IQMIX4110 2B3 Figure 8 IQMIX4111 3B3...

Page 14: ...IQMIX25 26 40 41 Introduction Issue 1 Rev 4 Page 14 2017 SAM Figure 9 IQMIX2500 2B3 Figure 10 IQMIX2501 3B3 Figure 11 IQMIX2600 2B3...

Page 15: ...IQMIX25 26 40 41 Introduction Issue 1 Rev 4 Page 15 2017 SAM Figure 12 IQMIX2601 3B3...

Page 16: ...to SMPTE 424M 425M level A compatible HD SDI to SMPTE292M 274M 296M SD SDI to SMPTE259M C 10G Ethernet to IEEE 802 3 Rollcall control and monitoring compatible with standard logging and reporting feat...

Page 17: ...with standard logging and reporting features 1 6 Enclosures The IQMIX fits the enclosure shown Ensure that the supplied cooling fan module is also fitted as described in section 1 6 2 1 6 1 B style En...

Page 18: ...rear 2 Remove the screws securing the blanking plate covering the chosen slot position Remove and store the blanking plate in a safe place for future use 3 Ensuring correct orientation fit the fan mo...

Page 19: ...le HD SDI to SMPTE292M 274M 296M SD SDI to SMPTE259M C DensiShield Inputs 2 0 1 1 0 2 DensiShield connectors In Out 16 0 0 16 8 8 SDI In Out Connector Format DensiShield pair Conforms to 3G SDI to SMP...

Page 20: ...ellow None Red Logging Input Status Input Alarms Output Alarms Output Status Misc RollTrack controls On off Index Source Address Command Status Sending Setup Versions reset defaults restart Specificat...

Page 21: ...physical input and output connections provided by the IQMIX modules 3 1 SDI BNC Input Outputs 3 2 10 25G Ethernet SFP 3 3 40G Ethernet QSFP 3 4 DensiShield 16 x 3G HD SD SDI interfaces provided with...

Page 22: ...l BOARD CPU BOARD Green flashing PTP SYNC OK Off PTP SYNC Fail PTP REF REF Green flashing Watchdog timer OK 8 16 1 8 Input port status Green OK Red Fail Yellow TPG 9 16 Output port status Green OK Red...

Page 23: ...the pages 5 2 1 Template Pages The following pages are available Configuration see section 5 4 Time Sync Configuration see section 5 5 Link Control see section 5 6 TPG Test Pattern Generator see sect...

Page 24: ...ressing the ENTER key or clicking the Save Value button Clicking an associated Preset Value button returns the value to the factory default setting 5 3 Information Display The Information display pane...

Page 25: ...Displays how input and output spigots are currently configured See Card Firmware Software Version below for information on how to change this Where Am I Causes the front edge LEDs to flash allowing t...

Page 26: ...thernet interfaces Card Firmware Software Version Each software version contains multiple firmware images These allow different spigot input output and flow standard combinations to be selected Select...

Page 27: ...e system NTP Configuration To add an NTP server enter the server s IP address in to the New field PTP Network Interface Click check boxes to select the required network interfaces If an interface fail...

Page 28: ...of the Status panel the Histogram provides a graphical representation of the distribution of differences between the card s clock and the PTP grandmaster clock Every time the clock difference is reca...

Page 29: ...l The Link Control page allows quad link 4K inputs to be synchronized by the IQMIX module To have the IQMIX synchronize quad link inputs enable the check box next to the set of inputs to synchronize T...

Page 30: ...generator allows a caption to be overlaid on the video essence Figure 20 TPG Page Option Operation TPG Select the test pattern to apply to the spigot from the drop down list Audio Freq Select the audi...

Page 31: ...ion Operation FEC Clause 74 Allows low latency FEC Clause 74 error correction to be used Options are On Off Status Displays lock status for each SFP FEC Stats Displays the number of corrected and unco...

Page 32: ...all Control Panel Issue 1 Rev 4 Page 32 2017 SAM Where N is the SFP number Log Field Description FEC_N_CORRECTED_ ERRORS Number of corrected errors for FEC N FEC_N_UNCORRECTED_ ERRORS Number of uncorr...

Page 33: ...and allows a static IP address to be defined Enter information as required then click S to save New settings are applied when Restart is clicked Where am I Checkbox When enabled the Where Am I functi...

Page 34: ...ev 4 Page 34 2017 SAM 5 10 Ethernet 1 and 2 RTP Sender The RTP Sender page displays the amount of data transmitted on a spigot by spigot basis Units are megabits per second Click Enable Stats to displ...

Page 35: ...SAM 5 11 Ethernet 1 and 2 RTP Receiver The RTP Receiver page displays the amount of data received plus details of packet loss on a spigot by spigot basis Units are megabits per second Click Enable St...

Page 36: ...1 Spigot Pane The Spigot pane provides basic monitoring for the selected Spigot Click Take to apply any changes made The Spigot pane details Spigot direction Associated BNC connector Current status T...

Page 37: ...use an Ethernet connector for this spigot Format Select the format to be used on this spigot This will ensure that the appropriate level of bandwidth is allocated 5 12 1 2 Flow Pane The Flow pane all...

Page 38: ...ctor Current status The last Take performed on the spigot Audio Delay Move the slider to set an Audio Delay as required Click P to return to the preset default value Make Break Mode Specifies how chan...

Page 39: ...evel of bandwidth is allocated 5 12 2 2 Flow Pane The Flow pane provides status information for video audio and metadata It also allows the video output standard loopback and multicast IP port details...

Page 40: ...vailable to a logging device connected to the RollCall network Each logging page comprises three columns Log Enable Select the check boxes that correspond to the parameters for which log information s...

Page 41: ...here n is the RollTrack index or indices which are failing Disabled REAR_ID Reports the code number of the rear fitted REAR_STATUS Reports the status of the rear where it can be determined SLOT_WIDTH...

Page 42: ...he current standard deviation in the network delay time between the card and the clock sending the synchronization messages Should be a low number as the network delay is expected to be constant TIMES...

Page 43: ...Mbit s Full Duplex 100 Mbit s Half Duplex 1 Gbit s Full Duplex No Link LAN_PORT_N_IPADDRESS Ethernet port IP address LAN_PORT_N_MACADDRESS Ethernet port MAC address LAN_PORT_N_STATE Ethernet connectio...

Page 44: ...he logging field Log Value Displays the current log value The following options are available Enable check boxes to activate log fields as required Figure 32 Logging SFP Page Log Field Description SFP...

Page 45: ...voltage reading VOLTAGE_N_STATE Displays temperature sensor state Valid values are OK WARN Low Low but in tolerance WARN High High but in tolerance SFP_N_WAVELENGTH Displays transmit wavelength in nm...

Page 46: ...arameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value The following options are available Enable check boxes...

Page 47: ...to select the fields to be enabled for each available spigot Depending on whether the spigot is an input or an output the appropriate log fields are shown An additional field is provided for the user...

Page 48: ...ood FAIL input signal not detected INPUT_N_TYPE HD SD 3G SDI INPUT_N_STANDARD PAL NTSC 625 Mono 525 Mono OUTPUT_N_IDENT Name of the output as shown on the rear panel OUTPUT_N_NAME Name of the output a...

Page 49: ...ack outputs to be set up Dragging the slider selects the RollTrack Index number displayed below the slider Clicking P selects the default preset value 5 17 3 RollTrack Source The source of information...

Page 50: ...a code in to the text field and then selecting S to save the selection Clicking P returns to the default preset command A RollTrack command consists of two sets of numbers for example 84 156 The firs...

Page 51: ...a redundant backup in case of Ethernet failure If an Ethernet failure is encountered 1 Use the matrix radio buttons to specify which inputs should be routed to which outputs 2 Select the Video Flow t...

Page 52: ...ut picture Figure 38 Setup Page Item Description Product Name of the module Software Version Currently installed software version number Firmware Version Currently installed firmware version number Se...

Page 53: ...ane The Ethernet pane displays details of the currently selected network interface and allows a static IP address to be defined Enter information as required then click S to save New settings are appl...

Page 54: ...IQMIX25 26 40 41 RollCall Control Panel Issue 1 Rev 4 Page 54 2017 SAM 5 22 Interop Page Not currently used Figure 41 Interop Page...

Page 55: ...working as expected follow these instructions 1 Select the appropriate SFP type from the SFP Database List and click Take Verify whether the SFP is now working correctly if so no further action is req...

Reviews: