IQMIX25/26/40/41
RollCall Control Panel
Issue 1 Rev 4
Page 41
© 2017 SAM
The following options are available. Enable check boxes to activate log fields as required.
Log Field
Description
SN=
Reports the module serial number, which consists of an
S
followed by eight digits.
Note
: this cannot be deselected.
OS_VERSION=
Reports the operating system name and version.
BUILD_NUMBER=
Reports the build number.
HARDWARE_VERSION=
Reports the hardware version number.
HARDWARE_MOD=
Reports the hardware modification number.
FIRMWARE_VERSION=
Reports the firmware version number.
POWER_USAGE=
Reports the power usage in Watts (A-type rack)/PR Units
(B-type rack).
UPTIME=
Reports the time since the last restart in the format
ddd:hh:mm:ss
.
ROL_STATES=
Reports the RollCall status. Valid values are:
•
OK
•
FAIL:n
where
n
is the RollTrack index or indices
which are failing
•
Disabled
REAR_ID=
Reports the code number of the rear fitted.
REAR_STATUS=
Reports the status of the rear where it can be determined.
SLOT_WIDTH=
Reports the slot width. IQMIX modules are available in
single and triple width.
SLOT_START=
Reports the slot in the rack where IQMIX is located.
TEMP_
N
_NAME=
Temperature measurement name.
TEMP_
N
_CELSIUS=
Reports the temperature status of the FPGA.
REFERENCE_
N
_SOURCE=
Reports time reference source.
REFERENCE_
N
_STATE=
Valid values are:
•
OK: Locked
•
OK: Input
•
WARN: Freerun
•
WARN: CrossLock
TIMESYNC_
N
_MODE=
Valid values are:
•
Free running:
Card is using its own clock with no
reference to any other source
.
•
PTP Multicast:
Card is synchronizing to a PTP
grandmaster clock using multicast network
messages.
•
PTP Unicast:
As
PTP Multicast
but using the
delay request. Reply messages are unicast to
minimize network traffic
.
•
NTP
: Module clock is synchronized to an NTP
clock. Generally less precise than PTP.