88
6-7
2
1
Maintenance
6.3 Storage
When the unit will be stored for a several weeks or
longer, prepare the unit correctly:
•
Shut down the unit properly, refer to Section 5.2.4.
•
Remove the threaded shaft from the balancer.
•
Apply a thin layer of non-corrosive oil on all threads
and cones.
•
Wrap oiled items in paper to keep the parts dust-
free.
Before putting the unit into use again, clean all oiled
parts.
6.4 Changing the mains fuse
Refer to
Figure 6-7
.
•
Switch off the unit.
•
Unplug the power cable from the power outlet.
•
Remove the power cable from the machine mains
socket (
1, Fig. 6-7
).
•
Pull out the fuse holder (
2, Fig. 6-7
).
•
Replace the damaged fuse with another fuse having
an identical rating.
•
Return the unit to its original functioning state, by
following the steps above in reverse.