IN STAL LA TION
IN STAL LA TION RE QUIRE MENTS
Space Re quire ments
8
The dimensions of equipment are shown in Figure 1c
and Figure 2c. Adequate clearance at the front of the
equipment must be maintained for access and servicing.
Po si tion of the Display
9
The Nucleus 3 7000 Flat Panel Display is designed to
be Panel or Console mounted, allowing easy access
for the Operator.
Spec i fi ca tions
10
For details of the Weight, Power Supplies and
Compass Safe distances of the Flat Panel Displays,
refer to Table 1.
ELEC TRI CAL CON NEC TIONS
Ca ble Screens
11
The cable screens are not to be stripped back further
than is necessary to enable the cores to be connected.
All exposed screens must be covered with PVC sleeving to
prevent accidental contact with live terminals.
Ca ble Connections
12
The Flat Panel Display and associated Remote
Trackerball and On/Off Sounder are connected to the
processor as shown on Figure 1c and Figure 2c.
IN PUT SIG NALS
13
Inputs to the Flat Screen Displays comprise video
signals and power.
CON TROL SWITCHES
14
The control switches, located on the Front Panel of the
Flat Panel Display Unit, are used for positioning the
picture on the screen and configuring the picture
parameters.
15
Refer to paragraphs 58 to 83, for details of the Controls
and indications provided at the Flat Panel Display
units.
IN STAL LA TION
Flat Panel Displays
16
The Flat Panel displays are designed to be either
Panel-mounted or Console-mounted.
17
Refer to Figure 1c for installation of the 20.1-inch Flat
Panel Display and Figure 2c for installation of the
18-inch Flat Panel Display.
18
Mark out the the cut-out position for the Flat Panel
Display in the Panel or Console (as appropriate),
allowing sufficient space for cable access and ventilation,
and cut-out the aperture for the flat panel display.
19
Cut out the aperture for the Flat Panel Display and drill
the required bolt positions for fixings.
20
Fit the Flat Panel Display into the Panel/Console and
secure it in position, using the fixings supplied.
Pro ces sor Unit
21
Mark out the position of the Processor Unit, leaving
sufficient clearance for ventilation, cable access and
servicing.
22
Drill the required bolt positions and secure the
Processor unit in position, using the fixings supplied.
23
Feed the ship's cables through the base of the unit and
make the connections, as detailed in the appropriate
Interconnections diagram. Figure 3c - 20.1-inch Display or
Figure 4c - 18-inch Display.
On/Off Sounder Unit
24
Where the On/Off Sounder is to be panel mounted,
refer to Figure 5c and mark out the position of the
On/Off Sounder unit. Drill the required fixing positions and
secure the unit in position, using the fixings supplied.
25
Connect the On/Off Sounder unit to the Processor
Unit, as detailed in the appropriate interconnections
diagram.
Re mote Trackerball
26
Where the Remote Trackerball is to be mounted within
a console, refer to Figure 6c and mark out the position
of the Trackerball unit. Drill the required fixing positions and
secure the unit in position, using the fixings supplied.
27
Connect the Remote Trackerball to the Processor
Unit, as detailed in the appropriate interconnections
diagram.
May 01
8c.2
Original
KH 2020
Chap 8c
Summary of Contents for Kelvin Hughes Nucleus 3 5000 Series
Page 27: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 ii Amdt 1 KH 2020 Index Introduction ...
Page 73: ...THIS PAGE IS INTENTIONALLY BLANK KH 2020 Chap 2a July 03 2a 6 Amdt 5 ...
Page 101: ...THIS PAGE IS INTENTIONALLY BLANK May 01 3 6 Original KH 2020 Chap 3 ...
Page 109: ...THIS PAGE INTENTIONALLY BLANK July 03 viii Amdt 5 KH 2020 Index Chap 1 3 ...
Page 119: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 x Amdt 1 KH 2020 Contents Chap 4 5 ...
Page 150: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4b 12 Original KH 2020 Chap 4b ...
Page 157: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4c 6 Original KH 2020 Chap 4c ...
Page 163: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4c 14 Original KH 2020 Chap 4c ...
Page 176: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4c 28 Original KH 2020 Chap 4c ...
Page 234: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4f 6 Original KH 2020 Chap 4f ...
Page 257: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4f 30 Original KH 2020 Chap 4f ...
Page 275: ...THIS PAGE IS INTENTIONALLY BLANK July 03 5 18 Amdt 5 KH 2020 Chap 5 ...
Page 279: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 iv Amdt 1 KH 2020 Index Chap 4 5 ...
Page 309: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 xiv Amdt 1 KH 2020 Contents Chap 7 8 ...
Page 356: ...Original 7c 19 May 01 KH 2020 Chap 7c CD 2413 Figure 16c Modulator PCB Switches Test Points ...
Page 359: ...THIS PAGE IS INTENTIONALLY BLANK May 01 7c 22 Original KH 2020 Chap 7c ...
Page 381: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 7d 26 Amdt 1 KH 2020 Chap 7d ...
Page 425: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8a 22 Original KH 2020 Chap 8a ...
Page 445: ...THIS PAGE INTENTIONALLY BLANK July 03 8aA 16 Amdt 5 KH 2020 Chap 8a Annex A ...
Page 463: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8c 12 Original KH 2020 Chap 8c ...
Page 472: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8c 22 Original KH 2020 Chap 8c ...
Page 476: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8d 4 Original KH 2020 Chap 8d ...
Page 498: ...THIS PAGE IS INTENTIONALLY BLANK Original 8e 19 May 01 KH 2020 Chap 8e ...