![Smiths Kelvin Hughes Nucleus 3 5000 Series System Handbook Download Page 84](http://html.mh-extra.com/html/smiths/kelvin-hughes-nucleus-3-5000-series/kelvin-hughes-nucleus-3-5000-series_system-handbook_1305982084.webp)
PLOT MENU
Func tion
75
Provides a selection of functions: Guard zone
activities, i.e. switching ON/OFF and setting Variable
zone range and bearing (BRG); Deleting all plots and an
Electronic ARPA computer reset facility; Selecting Bow
Crossing Range (BCR) or Closest Point of Approach (CPA)
also contains selection of Reference Targets and Sectors.
The Labels function applies labels to the targets. The menu
also contains END which exits the menu.
Se lec tion
76
To select the Plot menu:
(1) H i g h l i g h t t h e P L O T b o x a n d p r e s s a n y
pushbutton.
(2) The Plot menu boxes appear in the lower
right-hand corner of the screen as shown below.
Ref. Tar get
77
To operate the Reference Target function:
(1) Select a target on the Radar screen, highlight the
REF TGT box, the pop-down menu reads; Fix,
Unfix, Anchor.
(2) Press the appropriate pushbutton to Fix (Unfix)
the selected target. An ‘R’ appears on the selected
target and the Drift Input changes to ‘Fixed
Target’. If ‘Anchor Target’ is selected the ‘R’ is
replaced with an anchor in a box, and the Drift
Input changes to Anchor Watch. When the limit is
violated, the Red Alarm box contains the words:
NOTES:
(1) After the Anchor Alarm has been acknowledged, the
target reverts to a reference target. If Anchor Watch is still
required, it must be reactivated.
(2) When more than one target is annotated as ‘Fixed’ the
ARPA may drop a reference target if that target’s
parameters vary considerably from those of other
Reference Targets.
(3) To reset the ARPA computer and to delete
all
plots, position the cursor in the DEL ALL box, the
box is now highlighted. Press any pushbutton to
reset the computer and to delete all plots.
A highlighted box appears with the words:
Sec tor Se lec tion (Not EU)
78
To include/exclude sectors:
(1) Ensure Footprint Acquisition Zones are turned off.
(2) Highlight the ZONES box, pop-down boxes
appear with: Sect, Poly, FAZ. Press the left-hand
pushbutton and the following menu appears:
(3) A Sector Storage Level indication is provided
along the bottom of the Sector Selection menu. If
the Sector storage becomes full a
SECTOR
STORAGE FULL
warning message is displayed
and some stored Sectors may need to be removed
to create space for new sectors.
(4) To load previously saved sectors, scroll the
selection box until required sector appears.
Highlight the sector and press the left-hand
pushbutton.
(5) To create a sector, highlight
[Create]
and press
any pushbutton. A dotted inclusive/exclusive
sector appears on the display, the information
menu states: Plot, Select. Press the centre
pushbutton to select that Sector. The following
menu appears:
(6) Press the left-hand pushbutton to activate the
sector.
(7) Place the cursor over the sector outline and press
the centre pushbutton. Set the sector size by
selecting and then moving each edge to the
required position, when correct press the centre
pushbutton.
KH 2020
Chap 2b
Amdt 5
2b.11
July 03
CD-4767
ANCHOR WATCH
ACKNOWLEDGE ALARM
CD-2081
CLICK AGAIN
NOW TO CONFIRM
ACTION
CD-2075
De-
Select
FAZ
Rings
Active
Rings
Active
CD-1958
Zones
Active
Rings
Off
Summary of Contents for Kelvin Hughes Nucleus 3 5000 Series
Page 27: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 ii Amdt 1 KH 2020 Index Introduction ...
Page 73: ...THIS PAGE IS INTENTIONALLY BLANK KH 2020 Chap 2a July 03 2a 6 Amdt 5 ...
Page 101: ...THIS PAGE IS INTENTIONALLY BLANK May 01 3 6 Original KH 2020 Chap 3 ...
Page 109: ...THIS PAGE INTENTIONALLY BLANK July 03 viii Amdt 5 KH 2020 Index Chap 1 3 ...
Page 119: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 x Amdt 1 KH 2020 Contents Chap 4 5 ...
Page 150: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4b 12 Original KH 2020 Chap 4b ...
Page 157: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4c 6 Original KH 2020 Chap 4c ...
Page 163: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4c 14 Original KH 2020 Chap 4c ...
Page 176: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4c 28 Original KH 2020 Chap 4c ...
Page 234: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4f 6 Original KH 2020 Chap 4f ...
Page 257: ...THIS PAGE IS INTENTIONALLY BLANK May 01 4f 30 Original KH 2020 Chap 4f ...
Page 275: ...THIS PAGE IS INTENTIONALLY BLANK July 03 5 18 Amdt 5 KH 2020 Chap 5 ...
Page 279: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 iv Amdt 1 KH 2020 Index Chap 4 5 ...
Page 309: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 xiv Amdt 1 KH 2020 Contents Chap 7 8 ...
Page 356: ...Original 7c 19 May 01 KH 2020 Chap 7c CD 2413 Figure 16c Modulator PCB Switches Test Points ...
Page 359: ...THIS PAGE IS INTENTIONALLY BLANK May 01 7c 22 Original KH 2020 Chap 7c ...
Page 381: ...THIS PAGE IS INTENTIONALLY BLANK Sep 01 7d 26 Amdt 1 KH 2020 Chap 7d ...
Page 425: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8a 22 Original KH 2020 Chap 8a ...
Page 445: ...THIS PAGE INTENTIONALLY BLANK July 03 8aA 16 Amdt 5 KH 2020 Chap 8a Annex A ...
Page 463: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8c 12 Original KH 2020 Chap 8c ...
Page 472: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8c 22 Original KH 2020 Chap 8c ...
Page 476: ...THIS PAGE IS INTENTIONALLY BLANK May 01 8d 4 Original KH 2020 Chap 8d ...