Default settings
Item
Default setting
Page
[F 1]/[ oUt1]
[ oU1] Output mode (OUT1)
[ HYS] Hysteresis mode
[ 1ot] Switch operation (OUT1)
[ 1_P] Normal output
[ P_1] Set value (OUT1)
50% of maximum rated flow
[ 2.00] 2.00 L/min (4 L type)
[ 8.0] 8.0 L/min (16 L type)
[ 20.0] 20.0 L/min (40 L type)
[ 50] 50 L/min (100 L type)
[ 126] 126 L/min (250 L type)
Page
[ H_1] Hysteresis (OUT1)
5% of maximum rated flow
[ 0.20] 0.20 L/min (4 L type)
[ 0.8] 0.8 L/min (16 L type)
[ 2.0] 2.0 L/min (40 L type)
[ 5] 5 L/min (100 L type)
[ 12] 12 L/min (250 L type)
[ CoL] Display colour (OUT1)
[ SoG] ON: Green, OFF: Red
[F 2]/[ oUt2]
[ oU2] Output mode (OUT2)
[ HYS] Hysteresis mode (Flow)
[ 2ot] Switch operation (OUT2)
[ 2_P] Normal output
[ P_2] Set value (OUT2)
50% of maximum rated flow
[ 2.00] 2.00 L/min (4 L type)
[ 8.0] 8.0 L/min (16 L type)
[ 20.0] 20.0 L/min (40 L type)
[ 50] 50 L/min (100 L type)
[ 126] 126 L/min (250 L type)
[ H_2] Hysteresis (OUT2)
5% of maximum rated flow
[ 0.20] 0.20 L/min (4 L type)
[ 0.8] 0.8 L/min (16 L type)
[ 2.0] 2.0 L/min (40 L type)
[ 5] 5 L/min (100 L type)
[ 12] 12 L/min (250 L type)
[F 3]/[ RES]
[ rES] Response time setting
[ 1.00] 1 second
Page
[F10]/[ SUb]
[ SUb] Selection of sub screen
[ oUt] Display of set value (OUT1)
(Without temperature sensor)
Page
[ tEMP] Display of fluid temperature
(With temperature sensor)
[F20]/[ iNP]
[ inP] Setting of external input
[REACUM] Accumulated flow external reset
Page
[F22]/[ AnA]
[ AnA] Setting of analogue output
[ FLoW] Analogue output of flow
(Without temperature sensor)
Page
[ tEMP] Analogue output of temperature
(With temperature sensor)
[ FrE] Free range
[ oFF] Free range: OFF
[F30]/[ SAVE]
[SAvE] Storing of accumulated flow
[ oFF] OFF [not held]
Page
[F80]/[ dSP]
[ dSP] Setting of power saving mode
[ oN] No setting [display is turned on]
Page
[F81]/[ PiN]
[ Pin] Setting of security code
[ oFF] OFF
Page
[F82]/[ LiNE]
[ LinE] Input of line name
[ * * * * * * ] No name ******
Page
[F90]/[ ALL]
[ ALL] Setting of all functions
[ oFF] OFF
Page
[F98]/[ tESt]
[ tESt] Output check
[ NoRMAL] OFF
Page
[F99]/[ iNi]
[ ini] Reset to the default settings
[ oFF] OFF
Page
Summary of Contents for PF3W7 Series
Page 12: ...11 No PF OMM0005 N Model Indication and How to Order Metal piping...
Page 13: ...12 No PF OMM0005 N Polyvinyl chloride piping...
Page 45: ...44 No PF OMM0005 N List of output modes for fluid temperature...
Page 48: ...47 No PF OMM0005 N Example of display of sub screen...
Page 49: ...48 No PF OMM0005 N Example of display of sub screen continued...
Page 78: ...77 No PF OMM0005 N PF3W711 Vinyl chloride piping PF3W721 Vinyl chloride piping...