Mounting and Installation
Installation
Use the product within the specified operating pressure and temperature range.
Proof pressure could vary according to the fluid temperature. Check the characteristics data for operating
pressure and proof pressure.
Mounting
Never mount the product in a location where it will be used as a support.
Mount the product so that the fluid flows in the direction indicated by the arrow on the side of the body.
Check the flow characteristics data for pressure loss and the straight inlet pipe length effect on accuracy
), to determine inlet piping requirements.
Do not sharply reduce the piping size.
The monitor with integrated display can be rotated. It can be set at 90
o
intervals clock and anticlockwise, and
also at 45
o
and 225
o
clockwise. Rotating the display with excessive force will damage the end stop.