-14-
No.PF
※※
-OMM0005-N
Summary of Product parts
Body
1
DC(+)
2
OUT2
3
DC(-)
4
OUT1
Element
Description
Connector
Connector for electrical connections.
Lead wire with M8 connector
Lead wire to supply power and transmit output signals.
Piping port
Port to connect the fluid inlet at IN and fluid outlet at OUT.
Bracket
Bracket for mounting the product.
Temperature sensor
Sensor for detecting the fluid temperature.
Flow adjustment valve
Restricting valve to adjust the flow rate.
Flow adjustment knob
Knob for adjusting the flow rate.
Lock ring
Ring for locking the flow adjustment valve.
Display
Displays the flow, settings and error codes (See below).
Display
Element
Description
Main screen (2-colour display)
Displays the flow, the status of setting mode and error code.
Sub screen
Displays the accumulated flow, set value, peak/bottom value, fluid temperature and
line names.
Output display (Indicator LED)
Displays the output status of OUT1 and OUT2. When ON: Orange LED is ON.
Unit display
Displays the unit selected.
UP button
Selects a mode and the display shown at the sub screen, and increases the
ON/OFF set values.
SET button
Press this button to select mode and to confirm a set value.
DOWN button
Selects a mode and the display shown at the sub screen, and decreases the
ON/OFF set values.
Summary of Contents for PF3W7 Series
Page 12: ...11 No PF OMM0005 N Model Indication and How to Order Metal piping...
Page 13: ...12 No PF OMM0005 N Polyvinyl chloride piping...
Page 45: ...44 No PF OMM0005 N List of output modes for fluid temperature...
Page 48: ...47 No PF OMM0005 N Example of display of sub screen...
Page 49: ...48 No PF OMM0005 N Example of display of sub screen continued...
Page 78: ...77 No PF OMM0005 N PF3W711 Vinyl chloride piping PF3W721 Vinyl chloride piping...