-23-
No.PF
※※
-OMM0005-N
■
Wiring
Wiring of connector
Connections should only be made with the power supply turned off.
Use separate routes for the Flow switch wiring and any power or high voltage wiring. Otherwise,
malfunction may result due to noise.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode
power supply. When a switch-mode power supply is connected to the product, switching noise will be
superimposed and the product specification can no longer be met. This can be prevented by inserting a
noise filter, such as a line noise filter and ferrite core, between the switch-mode power supply and the
product, or by using a series power supply instead of a switch-mode power supply.
Pin No.
Description
Wire colour
1
DC(+)
Brown
2
OUT2
White
3
DC(-)
Blue
4
OUT1
Black
: When using the lead wire with M8 connector included with the PF3W7 series.
Tighten the connector by hand.
Summary of Contents for PF3W7 Series
Page 12: ...11 No PF OMM0005 N Model Indication and How to Order Metal piping...
Page 13: ...12 No PF OMM0005 N Polyvinyl chloride piping...
Page 45: ...44 No PF OMM0005 N List of output modes for fluid temperature...
Page 48: ...47 No PF OMM0005 N Example of display of sub screen...
Page 49: ...48 No PF OMM0005 N Example of display of sub screen continued...