-11-
PS##-OMM0003-A
■
Definition and terminology
Terms
Meaning
2
2-color indication
There are two colors to indicate a value, changing in accordance with ON and
OFF of the switch output.
7
7-segment indication
When "8" is shown on the display. It is called 7-segment because 8 consists of 7
pieces of "- (segments)".
(Analog) current output
See "Analog output (function)".
Analog output (function)
Function to output the voltage in proportion to the pressure.
(Analog) voltage output
See "Analog output (function)".
Auto preset
A function of the Pressure switch to automatically setup pressure just by having
equipment hold and release a workpiece via vacuum adsorption. This function is
used in an application where vacuum adsorption of a workpiece needs to be
confirmed with a Pressure switch.
A
Auto shift
A function to correct the set value of the switch output in accordance with the
applied pressure in case the switch operation is unstable due to pulsation of
applied pressure. This function is used in applications such as vacuum
adsorption. The pressure when a signal is externally input is set as a reference
value with which the pressure that turns the switch on or off can be shifted.
B
Bottom value indication (mode) Shows the minimum pressure reached at that moment.
Chattering
The phenomenon caused
in the switch output type in which the output turns on
and off repeatedly at high frequency.
C
Chattering-preventing function
A function to delay the response time of switch output in order to prevent
chattering.
D
Digit (Min. setting unit)
Shows how precisely the pressure can be indicated or set by the digital Pressure
switch. When 1 digit = 1 kPa, the pressure is given with an increment of 1 kPa,
e.g., 1, 2, 3, …, 99, 100.
E
Error indication
With the self-diagnosis function given to the Pressure switch, it indicates that
there is a failure which could cause a switch failure.
Fine adjustment mode
See "Fine adjustment of indicated value".
Fine adjustment of indicated
value (function)
An indicated pressure value can be adjusted within the range of ±5% R.D.
(±5% of the indicated value). It is used if a true pressure value is known or to
correct the difference of an indicated value of the measurement equipment
nearby that measures the same pressure as the Pressure switch.
F.S. (full span/full scale)
Abbreviation for full span and full scale; means the maximum fluctuation range of
the Pressure switch rated value. For example, when the output voltage is 1 to
5[V], the F.S. will be 5-1 = 4[V]. (Reference: 1%F.S. = 4 × 0.01 = 0.04[V])
F
Function selection mode
It is a mode with which each function is set up, and it is a separate menu from
the pressure setup. If the setting needs to be changed at factory, "F
∗
", each item
can be set up. The items to be set up are: indication color, operation mode,
output type, response time, indication resolution, fine adjustment of indicated
value, use of auto preset, use of power-saving mode, and use of PIN number.
(Refer to "Function selection mode" on page 23.)
Summary of Contents for ISE80(H)
Page 17: ...16 PS OMM0003 A Mounting with panel mount adapter Rear piping Bottom piping...
Page 55: ...54 PS OMM0003 A Dimensions Z ISE80 02 Z ISE80 02L...
Page 56: ...55 PS OMM0003 A Z ISE80 N02 Z ISE80 N02L...
Page 57: ...56 PS OMM0003 A Z ISE80 F02 Z ISE80 C01...
Page 58: ...57 PS OMM0003 A Z ISE80 C01L Z ISE80 A2...
Page 59: ...58 PS OMM0003 A Z ISE80 A2L Z ISE80 B2...
Page 60: ...59 PS OMM0003 A Z ISE80 B2L...