[F 1] Setting of OUT1
Set output method of OUT1.
Output turns on when the pressure exceeds the set value. The default setting of output set value is a center
value of between atmospheric pressure and upper limit of the rated range.
Display color depends on OUT1 output condition. As default, Display is Green when output is turned on.
Display is Red when output is turned off.
For the operation of each setting item, refer to "List of output modes" on page 28.
<Operation>
Press the
or button in function selection mode to display [F 1].
Press the
button.
Move on to setting output mode.
Press the
button to set.
Move on to setting of reversed output.
Press the
button to set.
Move on to setting of pressure.
Setting of pressure
Set pressure based on setting procedure on page 22.
"P" changes to "n" while reverse output is selected. ([P_1]
→
[n_1])
Hysteresis mode: [P_1]
Window comparator mode: [P1L][P1H]
Press the
button to set.
Move on to setting of hysteresis.
Setting of output mode
Press the
or button to select output mode.
Setting of reversed output
Press the
or button to select reversed output.