-4-
PS##-OMM0003-A
Operator
♦
This operation manual is intended for those who have knowledge of machinery using pneumatic
equipment, and have sufficient knowledge of assembly, operation and maintenance of such
equipment. Only those persons are allowed to perform assembly, operation and maintenance.
♦
Read and understand this operation manual carefully before assembling, operating or providing
maintenance to the product.
■
Safety Instructions
Warning
■
Do not disassemble, modify (including changing the printed circuit board) or repair.
An injury or failure can result.
■
Do not operate the product outside of the specifications.
Do not use for flammable or harmful fluids.
Fire, malfunction, or damage to the product can result.
Verify the specifications before use.
■
Do not operate in an atmosphere containing flammable or explosive gases.
Fire or an explosion can result.
This product is not designed to be explosion proof.
■
Do not use the product in a place where static electricity is a problem.
Otherwise it can cause failure or malfunction of the system.
■
If using the product in an interlocking circuit:
•
Provide a double interlocking system, for example a mechanical system
•
Check the product regularly for proper operation
Otherwise malfunction can result, causing an accident.
■
The following instructions must be followed during maintenance:
•
Turn off the power supply
•
Stop the air supply, exhaust the residual pressure and verify that the air is released before performing
maintenance
Otherwise an injury can result.
Caution
■
Do not touch the terminals and connectors while the power is on.
Otherwise electric shock, malfunction or damage to the product can result.
■
After maintenance is complete, perform appropriate functional inspections and leak tests.
Stop operation if the equipment does not function properly or there is a leakage of fluid.
When leakage occurred from other parts except piping, the product might break.
Cut off power supply and stop supplying fluid.
Do not apply fluid at leaking condition.
Safety cannot be assured in the case of unexpected malfunction.
■
Use ferule made by Swagelock
®
(trade name: Swagelock
®
fittings) for TSJ fittings, packing and glands
made by Cajon (trade name: Cajon VCR
®
fittings) for URJ fittings.
Otherwise safety may not be secured due to leakage from joint.
When using ferules, packing or glands made by other manufacture, be sure to perform helium leak test to verify no
leakage.
Summary of Contents for ISE80(H)
Page 17: ...16 PS OMM0003 A Mounting with panel mount adapter Rear piping Bottom piping...
Page 55: ...54 PS OMM0003 A Dimensions Z ISE80 02 Z ISE80 02L...
Page 56: ...55 PS OMM0003 A Z ISE80 N02 Z ISE80 N02L...
Page 57: ...56 PS OMM0003 A Z ISE80 F02 Z ISE80 C01...
Page 58: ...57 PS OMM0003 A Z ISE80 C01L Z ISE80 A2...
Page 59: ...58 PS OMM0003 A Z ISE80 A2L Z ISE80 B2...
Page 60: ...59 PS OMM0003 A Z ISE80 B2L...