-31-
PS##-OMM0003-A
Press the
button to set.
Setting of [F 4] analog output/auto-shift input completed
Conditions and explanations for auto-shift function
•Keep constant pressure for 5 ms or longer from the close signal of auto-shift input.
•At auto-shift input, [ooo] is displayed for approximate 1 second. Pressure value at that time is
memorized as corrected value [C_5].
•With corrected value which is memorized, set value are compensated.
•Span is 10 ms or less until the switch output starts soon after auto-shift input.
•When the measured pressure exceeds the set pressure range at auto-shift input, corrected value is not
memorized and [o.r] is displayed for approximate 1 second.
•If the pressure is within the set pressure range and beyond the set value corrected by auto-shift
(including hysteresis) when the auto-shift input is applied, the set value is corrected to the upper limit or
lower limit (which is closer) of the set pressure range automatically. (The correction is performed when
the auto-shift input is applied at the pressure beyond the set pressure range. If the auto-shift input is
applied again at the pressure within the set pressure range, the correction is released and the product
operates along with the set value.)
•Completing pressure setting of OUT2, the corrected value and [C_5] will be displayed alternately.
Press the
button to return to the measurement mode.
•Corrected value [C_5] after auto-shift input will vanish when the power is off, and is reset to zero (Initial
value) when the power is re-supplied.
∗
: EEPROM is not used for memory corrected value.
For auto-shift input, the acceptable set range are as follows.
Set pressure range
Accepted set range
Compound
-110.0 to 110.0 kPa
-220 to 220 kPa
1 MPa
-0.105 to 1.100 MPa
-1.205 to 1.205 MPa
2 MPa
-0.105 to 2.20 MPa
-2.31 to 2.31 MPa
Vacuum
10.0 to -111.0 kPa
-121.0 to 121.0 kPa
Setting of effective output
Press the
or button to
select effective output.
Return to function selection
mode.
Summary of Contents for ISE80(H)
Page 17: ...16 PS OMM0003 A Mounting with panel mount adapter Rear piping Bottom piping...
Page 55: ...54 PS OMM0003 A Dimensions Z ISE80 02 Z ISE80 02L...
Page 56: ...55 PS OMM0003 A Z ISE80 N02 Z ISE80 N02L...
Page 57: ...56 PS OMM0003 A Z ISE80 F02 Z ISE80 C01...
Page 58: ...57 PS OMM0003 A Z ISE80 C01L Z ISE80 A2...
Page 59: ...58 PS OMM0003 A Z ISE80 A2L Z ISE80 B2...
Page 60: ...59 PS OMM0003 A Z ISE80 B2L...