Option L: Dryer with heavy duty auto drain.
The heavy duty auto drain to be assembled by customer.
10.1 Safety instructions for use
Refer to the instructions below when handling the product.
WARNING
- Before replacing the auto drain on the compressed air side confirm that the pressure gauge
indicates zero.
Removing the auto drain with any air pressure remains could arise to unexpected accident,
such as parts been expelled when being unscrewed.
- There is the possibility of damaging the condenser during the auto drain maintenance.
Follow enduser procedures ensure safety of operator. (example: Put on protective glass,
apron, and gloves)
10.2 Specifications
Part number
(Service parts)
Heavy duty auto drain
ADH4000-04
Replacement kit for
exhaust valve mechanism
ADH-E400
Auto drain type
Float type
Auto drain valve type
N.O. (Normally open)
Maximum specification pressure
1.6MPa
Operating pressure range
0.05 to 1.6 MPa
Maximum condensate discharge
0.024m
3
/h
(0.7 MPa, water)
Heavy duty
Auto drain
Housing
(Housing is
not replaced)
ADH-E400
Replacement kit for
exhaust valve
mechanism
ADH4000-04
Ball valve
Heavy duty auto drain