IDX-OM-V020
Chapter
3
Transportation and installation
IDFA60/70/80/90 Series
3.3
Cautions about Reinstallation
3-7
3.3 Cautions about Reinstallation
If you move the product and reinstall it into another place after some operations (including trial running),
all installation instructions in chapter 2 should be followed as well as the following instructions.
Disassembly of the power cable
Cut off the power source before you disassemble the power cable.
Removal of air piping
Remove the seal tape completely after detaching the piping. Remaining tape could cause imperfect
cooling or failure by entering into the product.
Procedure to release residual compressed air
1) Even while the dryer is removed, only open the bypass piping valve when compressed air is needed.
2) Close the compressed air inlet and outlet valves.
3) Ensure that the ball valve of the auto drain is opened.
4) Remove the drain cock holding clip.
5) Rotate the drain cock of the auto drain to "O" side, and exhaust the compressed air from the product.
Drain cock
“O”: (Open)
Remove the clip
Only someone who has enough knowledge about the product and incidental devices
should reinstall it in another place.
CAUTION
- Only qualified personnel should do the wiring work.
- Cut off the power supply for safety before the wiring. Wiring with the product energized is
strictly prohibited.
WARNING
- Only qualified personnel should do the wiring work.
- Separate the compressed air source from the product for safety before removing the
piping.
- Do not remove any piping when there is remaining compressed air pressure inside of it.
WARNING
Summary of Contents for IDFA60-23-A
Page 36: ...IDX OM V020 Chapter 7 Documents 7 5 Air Refrigerant Circuit IDFA60 70 80 90 Series 7 6...