IDX-OM-V020
Chapter
7
Documents
IDFA60/70/80/90 Series
7.1
Specifications
7-1
Chapter 7 Documents
7.1 Specifications
Models
Specification
IDFA60-23 IDFA70-23 IDFA80-23 IDFA90-23
Operati
ng
range
(Note 1)
Fluid
Compressed air
Inlet air temperature
o
C
5 to 65
Inlet air pressure
MPa
0.15 to 1.0
(Note 3)
Ambient temperature (Humidity)
o
C
2 to 45 (Relative humidity 85 % or less)
Rated
condition
Air flow
capacity
m
3
/h
Standard
condition
(ANR)
(Note 2)
Outlet air
pressure dew
point
3
o
C
204
312
552
810
Outlet air
pressure dew
point
7
o
C
300
408
654
900
Outlet air
pressure dew
point
10
o
C
360
480
720
960
Compressor
inlet
condition
(Note 3)
Outlet air
pressure dew
point
3
o
C
216
331
585
859
Outlet air
pressure dew
point
7
o
C
318
432
693
954
Outlet air
pressure dew
point
10
o
C
382
509
763
1,018
Inlet air pressure
MPa
0.7
Inlet air temperature
o
C
35
Ambient temperature
o
C
25
Power supply voltage (Frequency)
Single phase 230 VAC (50Hz)
Allowable voltage fluct/-10%
(Note 4)
Max. Air Flow Capacity
Air flow calculated with correction factor
(see the Chapter 7-2)
Electric
spec
Power consumption
(Note 5)
W
820
1300
1950
2220
Current consumption
(Note 5)
A
4.9
7.2
12.0
13.0
Applicable earth leakage breaker capacity
(sensitivity current: 30mA)
A
10
15
20
30
Cooling method
Air-cooled refrigeration
Refrigerant
R410A (HFC) GWP:2088
(Note 7)
Amount of refrigerant to be filled
g
390 +/- 10 530 +/- 10 630 +/- 10 780 +/- 10
Auto drain
Float type
(Normally open: Min. operating pressure 0.1 MPa)
Drain tube O.D.
mm
12
Piping port size
R1
R1 1/2
R2
Weight
kg
49
68
95
110
Coating color
Panel: Urban white 1
Base: Urban gray 2