# Remote registration
Registration for wireless communication between the base and remote.
For this wireless system, it is necessary to register the PID (Product ID) of each product to establish
communication without interference from another network.
The minimum required settings for registration of the base are pairing (change of operation mode)
and remote registration.
Register the dummy remote as necessary.
- Pairing
Select the operation mode of the base.
The remote can be registered only when "Pairing enable" is selected.
Pairing disable: Remote cannot be registered (communication with the registered remote will be
established).
Pairing enable: Remote and dummy remote can be registered.
When pairing is enabled, operation control of the registered remote cannot be performed through
communication.
- Remote registration
Register and delete the base to/from the remote; and check the registration status of the remote.
Refer to Wireless slave unit registration procedure for details.
- Dummy remote
Register the dummy remote to the base.
Refer to the Wireless unit registration procedure
- After changing the operation mode in the pairing setting, the mode is changed by clicking the
Reset
button or re-supplying power so that the mode will be changed to the remote registration
or listing for connection.