■Procedure 2 Setting / Installing the wireless unit
# Wireless system parameter list
- Remote (input / output) setting parameters
Classification
Parameter name
Set value
Initial value
Setting when
not energized
Notes
Setting
a)
Output while
communication
is not
established
CLEAR/HOLD
CLEAR
Available
Setting the output operation while the
fieldbus communication is
disconnected.
b)
Wireless
communication
Active/Idle
Active
Available
If it is set to "Idle", the wireless
communication is disconnected.
Information
TAG
Max. 15 characters
Product number
Available
Letters which can be input are half-
width characters (alphabets,
numbers, symbols) that correspond
to ASCII code.
Writing from the base to the remote
is not possible during a non-
energized state.