# Output unit
Remote grommet output type LED indicator
- Remote grommet output type LED indicator specifications
LED name
Function
Color of LED
Single Operation
PWR
Indicates the power
supply voltage (US1/
US2) status
Green LED is ON.
Normal power supply voltage for control and input
(US1) ON, and normal power supply voltage level for
output (US2)
Red LED flashes.
Abnormal power supply voltage level for output (US2)
(Applicable when the power supply voltage monitor is
enabled)
OFF
Power supply for control and input (US1) is not
supplied.
MS
Status of remote output
Green LED is ON.
Operating normally
Red LED flashes.
Restorable error is detected.
- Short-circuit detection of output load
- Abnormal power supply voltage for control and input
(US1)
(Applicable when the power supply voltage monitor is
enabled)
Red LED is ON
Unrestorable error is detected.
OFF
Power supply for control and input (US1) is not
supplied.
W-SS
Radio wave receiving
intensity
Green LED is ON.
Received radio wave intensity level 3
Green LED flashes
(1Hz)
Received radio wave intensity level 2
Green LED flashes
(2Hz)
Received radio wave intensity level 1
Red LED flashes.
Wireless communication is not connected.
OFF
Base not registered
W-NS
Wireless
communication
connection status
Green LED is ON.
Remote output connected correctly
Red LED flashes.
Remote output not connected
Red LED is ON
Remote output not connected
(Non-restorable error in wireless communication)
Red/green
Wireless communication connection is being
configured (pairing)
Orange LED is ON Forced output mode is ON
OFF
Base not connected
* If there are multiple conditions for LED ON/Flashing, the detailed information can be seen only when the setting of the diagnostic