39
After reviewing of number of brake operation, press
WRITE to switch to next input operation. The display
will indicate PRG STEP P7 and present origin
detection time.
Next, enter desired origin detection time. The setting
range is 0
~
9.99sec (1 unit as 10msec). Set the date
with taking into the consideration of cylinder
operating conditions.
After the above setting, press WRITE to switch to
next input operation. The display will indicate PRG
STEP P8 and present operating error detection time.
Next, enter desired operating error detection time.
The setting range is 0
~
9.99sec (1 unit as 10msec).
Set the data with taking into the consideration of
cylinder operating conditions.
After the above setting, press WRITE to end the
whole preset operation.
9-1-3 Confirmation of Set Data
Turn the controller switching mode to PRESET.
PRG
STEP P7
″
″
″
〟
200
Blinking
PRG
STEP P8
″
″
″
〟
Blinking
200
PRG
STEP P1
″
″
″
〟
1000.0
″
″
″
〟
UP
DOWN
P1
P2
P3
P4
P8
P5
P6
P7
When P1 is blinking, use UP & DOWN key to
reconfirm each and individual preset value.
When the input value is blinking, press READ
once to shift the operation back to P1.