11-10
Troubleshooting
Using the Event Log To Identify Problem Sources
T
rou
bl
esh
oot
in
g
Using the Event Log To Identify Problem
Sources
The Event Log records operating events as single-line entries listed in chrono-
logical order, and serves as a tool for isolating problems. Each Event Log entry
is composed of five fields:
Severity
is one of the following codes:
I
(information) indicates routine events.
W
(warning) indicates that a service has behaved unexpectedly.
C
(critical) indicates that a severe switch error has occurred.
D
(debug) reserved for SMC internal diagnostic information.
Date
is the date in
mm/dd/yy
format that the entry was placed in the log.
Time
is the time in
hh:mm:ss
format that the entry was placed in the log.
System Module
is the internal module (such as “ports” for port manager) that
generated the log entry. If VLANs are configured, then a VLAN name also
appears for an event that is specific to an individual VLAN. Table 11-1 on page
11-11 lists the individual modules.
Event Message
is a brief description of the operating event.
The event log holds up to 1000 lines in chronological order, from the oldest to
the newest. Each line consists of one complete event message. Once the log
has received 1000 entries, it discards the current oldest line each time a new
line is received. The event log window contains 14 log entry lines and can be
positioned to any location in the log.
The event log will be
erased
if power to the switch is interrupted.
(The event log is
not
erased by using the
Reboot Switch
command in the Main
Menu.)
Severity
Date
Time
System Module
Event Message
I 08/05/98 10:52:32 ports: port 1 enabled