IDP 800 Terminal Series - Hardware Guide
© SkyWave Proprietary 19 T209, Version 01
3.3 RF Connector
The IDP-800 is optionally available to support a remote antenna. The remote antenna
terminal variant uses an SMA panel connector.
The terminal must only be used with an active SkyWave antenna. Refer to APPENDIX A
for antenna order part numbers.
Table 13
RF Connector
Parameter
Value
Antenna Connector
SMA female, normal polarity
Maximum Cable Length
8 m
3.3.1 Antenna Cut Detection
For remote antenna versions, the terminal can detect when the antenna is disconnected. It
detects the antenna disconnect by monitoring the DC current to the antenna when it is
receiving either a GPS or IsatData Pro signal.
3.4 Pass-Through Mode
The terminal operates in pass-through mode when there is no application firmware
present. A block diagram of pass-through mode is shown in Figure 9. In pass-through
mode, the terminal connects the modem's serial interface to the terminal's
RS-232 port.
Figure 9
Pass-Through Mode Signals
The terminal's I/O lines are configured as per Table 14 when in pass-through mode. The
modem's serial data and the EVENT_NOTIFICATION pins are connected to the
terminal's external connector.
Table 14
Pass-Through Mode Power
I/O Pin
State
Specification
I/O 02
Output
Connected to EVENT_NOTIFICATION
I/O 01 and I/O 03
Analog Input
Do not use
RS-232
RS-232
Disabled if no valid RS-232 level on receiver
When in pass-through mode, there are no inputs for the application controller to sample.
Pass-through mode time specifications are given in Table 15.
Terminal
Modem
RS-232
EVENT NOTIFICATION
I/O 02
RS-232