65
3.6.4
Cable and Connector
The REMOTE BAR GRAPH uses a single cable to communicate with and receive power from the
computer unit. The cable is not removable and is a fixed length. Do not discard the excess cable when
the unit is installed. Extending this cable is not recommended.
There is a single connector on the far end of the cable. It is possible for the pins and sockets within the
connector to be damaged. A pin may be bent, broken, or “pushed back” inside the housing.
3.6.5
Moisture
The REMOTE BAR GRAPH protects against dust and water when correctly installed. It is not possible
to fully protect the sensitive electronic assembly inside against pressure-washing or heavy rainfall. If
this occurs, replace the remote bar graph.
3.6.6
Remote Bar Graph Replacement
Removal of Remote Bar Graph
1. Turn off the power.
2. Remove the display console in order to access the cabling and connectors.
3. Disconnect the remote bar graph cable, from the display console wire harness, at the rear of the
display console.
4. Remove the remote bar graph from its bracket by loosening and removing the knob at each end
of the remote bar graph. Retain the knobs for reuse.
Installation of Remote Bar Graph
1. Position the new remote bar graph on the bracket
2. Connect and tighten the knobs at each end.
3. Route the cable to the display console and connect the cable.
4. Turn the power on, and verify that the bar graph is operating correctly.