25
2.6.5
Menu 04 - Span Sensor
This menu allows the user to enter the values for the Span Sensor and Angle Span.
1. Press the
04 Span Sensors
button to enter the routines for spanning the Angle and Extension
Sensors.
WARNING!
ENSURE THE AREA AROUND THE CRANE IS SAFE PRIOR TO EXTENDING THE BOOM.
2. Raise the boom to at least a 60° angle. Verify with a digital level.
3. Ensure the crane setup is adequate, then raise the boom and fully extend the boom sections.
4. Press the
Next
button to access the “No. 2 = XX.XX.” Press the
No. 2 = XX.XX
button to
calibrate the span for No. 2.
5. Press the
Yes! Calibrate!
button to access the Number Entry screen for Extension Span.
6. Enter the Span Number for extension using the numbers calculated from the pin-to-pin boom
measurement.
7. After number entry, press the
Exit
button and the display will return to the span No. 2 Menu.
TEST
SET
TEST
SET
SkyAzúl, Equipment Solutions
www.skyazul.com
301-371-6126