31
2.6.8
Menu 07 - Radius/Moment
This menu is used to calibrate the radius and moment of the boom.
1. Press the
Next
or
Prev
butto
ns until “07 Radius/Moment” appears in the information window at
the right.
ENSURE THE CRANE IS SET UP IN ACCORDANCE WITH THE MANUFACTURER’S
OPERATION MANUAL FOR MAXIMUM STABILITY. ENSURE THAT ALL BOOM
EXTENSIONS AND LOADS LIFTED ARE WITHIN THE APPROPRIATE LOAD CHARTS
AND LIMITS. FAILURE TO COMPLY WITH MANUFACTURER’S LIMITS MAY RESULT IN
SERIOUS INJURY OR DEATH.
IMPORTANT!
ANY ATTACHMENTS ON THE SIDE OR TIP OF THE BOOM DURING THESE TESTS CAN
CAUSE INACCURACY IN THE MAIN BOOM MOMENT IF THE SETUP OR STORED
INFORMATION IS INCORRECT.
RCI514 Radius Moment Calibration
BOOM MODE A: Perform two Radius Moments, fully retracted and fully extended.
BOOM MODE B: Perform four Radius Moments at fully retracted, ½ Boom Length, ¾ Boom Length and
fully extended.
Enter Calibration Mode and press Next button to menu to 07 Radius / Moment